MKZI20 Datasheet, PDF (1/8 Pages) Minmax Technology Co., Ltd. – vibration and thermal shock meets en61373 | |||
|
®
MKZI20 SERIES
DC/DC CONVERTER 20W, Reinforced Insulation, Railway Standard
FEATURES
âºIndustrial Standard 2"x1" Package
âºInput Ranges 9-36VDC, 18-75VDC, 40-160VDC
âºI/O Isolation 2250VDC with Reinforced Insulation
âºOperating Temp. Range -40°C to +88°C
âºNo Min. Load Requirement
âºOver Load/Voltage and Short Circuit Protection
âºRemote On/Off, Output Voltage Trim
âºConducted EMI meets EN55022 Class A & FCC Level A
âºVibration and Thermal Shock meets EN61373
âºCooling, Dry & Damp Heat Test meet IEC/EN60068
âºRailway EMC Standard meets EN50121-3-2
âºRailway Standard meets EN50155 (IEC60571)
âºUL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking (Pending)
PRODUCT OVERVIEW
The MINMAX MKZI20 series is a new range of high performance 20W isolated dc-dc converter within encapsulated 2"x1" package which specifically design
for railway applications. There are 12 models available for railway input voltage of either 24(9~36)VDC or 48(18~75)VDC or 72/110(40~160)VDC and tight
output voltage regulation. Further features include over current, over voltage, short circuit protection, remote ON/OFF, output trim and EMI filter meets
EN55022 & FCC Part15 Class A as well. MKZI20 series conform to vibration and thermal shock test meets EN61373, cooling, dry and damp heat test
meets IEC/EN 60068-2 and railway EMC standard EN50121-3-2 and complies also with railway standard EN50155 (IEC60571). MKZI20 series offer an
highly reliable solution for critical applications in railway systems, battery-powered equipment, measure instrumentation and many critical applications.
Model Selection Guide
Model
Input
Number
Voltage
(Range)
VDC
MKZI20-24S05
MKZI20-24S12
MKZI20-24S15
MKZI20-24S24
24
( 9 ~ 36 )
MKZI20-48S05
MKZI20-48S12
MKZI20-48S15
MKZI20-48S24
MKZI20-110S05
48
( 18 ~ 75 )
MKZI20-110S12
MKZI20-110S15
MKZI20-110S24
110
( 40 ~ 160 )
Output
Voltage
VDC
5
12
15
24
5
12
15
24
5
12
15
24
Output Current
Input Current
Max.
@Max. Load @No Load
mA
mA(typ.)
mA(typ.)
4000
980
1670
960
25
1330
955
833
957
4000
490
1670
474
15
1330
472
833
473
4000
219
1670
212
10
1330
211
833
213
Over
Voltage
Protection
VDC
6.2
15
18
27
6.2
15
18
27
6.2
15
18
27
Max. capacitive
Load
μF
6800
1200
750
300
6800
1200
750
300
6800
1200
750
300
Efficiency
(typ.)
@Max. Load
%
85
87
87
87
85
88
88
88
83
86
86
85
Input Specifications
Parameter
Input Surge Voltage (100ms. max)
Start-Up Threshold Voltage
Under Voltage Shutdown
Start Up Time
Input Filter
Model
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
All Models
Min.
Typ.
Max.
Unit
-0.7
---
50
-0.7
---
100
-0.7
---
170
---
---
9
---
---
18
VDC
---
---
40
---
7.5
---
---
16
---
---
37
---
---
50
--
mS
Internal Pi Type
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/03/23 P6 Page 1 of 8
|
▷ |