English
Language : 

MKW15M Datasheet, PDF (1/5 Pages) Minmax Technology Co., Ltd. – fully regulated output voltage
®
MKW15M SERIES
DC/DC CONVERTER 15W, Reinforced Insulation, Medical Safety
FEATURES
►Industrial Standard 2" X 1" Package
►Wide 2:1 Input Voltage Range
►Fully Regulated Output Voltage
►I/O Isolation 4200VAC with Reinforced Insulation, rated for
300VAC Working Voltage
►Low Leakage Current < 5µA
►Operating Temp. Range -40℃ to +85℃
►No Min. Load Requirement
►Overload/Voltage and Short Circuit Protection
►Conducted EMI meets EN55022 Class A & FCC Level A
►UL/cUL/IEC/EN 60950-1 Safety Approval
►Medical Safety meets 2xMOPP per 3rd Edition of IEC/EN 60601-1
& ANSI/AAMI ES60601-1(Pending)
PRODUCT OVERVIEW
The MINMAX MKW15M series is a new range of high performance 15W isolated dc-dc converter in a compact 2"x1" package which specifically design for
medical applications. The I/O isolation is specified for 4200VACrms with reinforced insulation, which rated for 300VAC working voltage. All 15 models
available for 12, 24, 48VDC with wide 2:1 input voltage range and tight output regulation. Further features include over current, short circuit protection, no
min. load requirement and EMI meets EN55022 class A. The MKW15M series offer a economical solution for demanding applications in industrial and
medical instrumentation requesting a certified supplementary or reinforced insulation system to comply with industrial or latest medical safety standards
Model Selection Guide
Model
Input
Number
Voltage
(Range)
VDC
MKW15-12S05M
MKW15-12S051M
MKW15-12S12M
MKW15-12D12M
12
(9 ~ 18)
MKW15-12D15M
MKW15-24S05M
MKW15-24S051M
MKW15-24S12M
MKW15-24D12M
MKW15-24D15M
24
(18 ~ 36)
MKW15-48S05M
MKW15-48S051M
MKW15-48S12M
MKW15-48D12M
48
(36 ~ 75)
MKW15-48D15M
Output
Voltage
VDC
5
5.1
12
±12
±15
5
5.1
12
±12
±15
5
5.1
12
±12
±15
Output Current
Input Current
Max.
@Max. Load @No Load
mA
mA(typ.) mA (typ.)
3000
1453
3000
1483
1250
1404
20
±625
1420
±500
1404
3000
718
3000
733
1250
702
15
±625
694
±500
702
3000
355
3000
362
1250
355
10
±625
355
±500
355
Reflected
Ripple
Current
mA(typ.)
100
50
30
Over
Max. capacitive
Voltage
Load
Protection
VDC
μF
6.2
6.2
5100
15
870
±15
440#
±18
280#
6.2
6.2
5100
15
870
±15
440#
±18
280#
6.2
6.2
5100
15
870
±15
440#
±18
280#
# For each output
Efficiency
(typ.)
@Max. Load
%
86
86
89
88
89
87
87
89
90
89
88
88
88
88
88
Input Specifications
Parameter
Model
Min.
Typ.
Max.
Unit
12V Input Models
-0.7
---
25
Input Surge Voltage (100 ms max.)
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
12V Input Models
---
---
9
Start-Up Threshold Voltage
24V Input Models
---
---
18
VDC
48V Input Models
---
---
36
12V Input Models
---
7.5
---
Under Voltage Shutdown
24V Input Models
---
15
---
48V Input Models
---
33
---
Start Up Time
Power Up
Nominal Vin and Constant Resistive Load
---
---
30
ms
Input Filter
All Models
Internal Pi Type
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/05/22 P5 Page 1 of 5