Key Features
y Efficiency up to 84%
y Isolation 5600VDC
y MTBF > 1,000,000 Hours
y 2:1 Wide Input Range
y Complies With EN55022 Class B
y All I/O Clearance and Creepage Distance
y 2.0 mm Min.
y Temperature Performance -40] to +75]
y Low Leakage Current
y Low Isolation Capacitance
y CSA60950-1 Safety Approval
y Industry Standard Pinout
y Short Circuit Protection
Low Profile
EMI
EN55022
5600
VDC
I/O Isolation
2:1
Wide Range
Minmax's MIHW1000-Series power modules are specially designed to provide ultra-high levels of isolation 5600VDC in a low profile 24-pin DIP
package. Operating input voltage ranges of 4.5-9VDC, 9-18VDC, 18-36VDC and 36-75VDC which provide precisely regulated output voltages of
5V, 12V, 24V ,{12V and {15VDC.
The -40] to +75] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments,
distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer
peripheral systems and industrial robot systems.
The modules have a maximum power rating of 3W and a typical full-load efficiency of 84%, continuous short circuit, EN55022 Class B conducted
noise compliance minimize design-in time, cost and eliminate the need for external filtering.
Absolute Maximum Ratings
Parameter
Min. Max. Unit
5VDC Input Models -0.7 11 VDC
Input Surge Voltage
( 1000 mS )
12VDC Input Models
24VDC Input Models
-0.7 25 VDC
-0.7 50 VDC
48VDC Input Models -0.7 100 VDC
Lead Temperature (1.5mm from case for 10 Sec.) --- 260 ]
Internal Power Dissipation
--- 2,500 mW
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions Min. Max. Unit
Ambient -40 +75 ]
Case
-40 +95 ]
-40 +125 ]
--- +95 %
Free-Air Convection
EN55022 Class B