English
Language : 

MIDR03M Datasheet, PDF (1/4 Pages) Minmax Technology Co., Ltd. – DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
®
MIDR03M SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
FEATURES
►3000VAC reinforced Insulation
►Insulation rated for 300VAC Working Voltage
►Medical Safety to UL/CSA/EN/IEC 60601-1 3rd Edition
►2 MOOP rated
►Fully regulated Output Voltage
►Low Leakage Current
►Operating Temp. Range –40°C to +75°C
►Input Filter meets EN 55022,class A and FCC, level A
►Short Circuit Protection
►Small DIP-24 Plastic Package
►3 Years Product Warrant
PRODUCT OVERVIEW
The MINMAX MIDR03M series is a new range of high isolation DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is
specified for 3000VACrms.The product comes in a small DIP-24 package. There are 15 models available for 5V,12V and 24V input voltage and single- or
dual-output voltage .The MIDR03M DC/DC converters offer a cost effective solution for applications in industrial controls, medical instrumentation and also
in consumer electronics requesting a certified supplementary or reinforced insulation system to comply with industrial or latest medical safety standards.
Model Selection Guide
Model
Input
Number
Voltage
MIDR03-05S05M
MIDR03-05S12M
MIDR03-05S15M
MIDR03-05D12M
MIDR03-05D15M
MIDR03-12S05M
MIDR03-12S12M
MIDR03-12S15M
MIDR03-12D12M
MIDR03-12D15M
MIDR03-24S05M
MIDR03-24S12M
MIDR03-24S15M
MIDR03-24D12M
MIDR03-24D15M
VDC
5 ±10%
12 ±10%
24 ±10%
Input Specifications
Parameter
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
Output
Voltage
VDC
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
Output Current
Max.
mA
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
Input Current
@Max. Load
mA(typ.)
1000
960
960
1000
1000
420
400
400
420
420
210
195
195
210
210
@No Load
mA(typ.)
130
60
40
Max. capacitive
Load
μF
470
220 #
470
220 #
470
220 #
# For each output
Efficiency
(typ.)
@Max. Load
%
60
62
62
60
60
60
62
62
60
60
60
64
64
60
60
Model
5V Input Models
12V Input Models
24V Input Models
5V Input Models
12V Input Models
24V Input Models
All Models
Min.
Max.
Unit
4.5
5.5
10.8
13.2
21.6
-0.7
26.4
7.5
VDC
-0.7
15
-0.7
30
---
0.5
A
---
2500
mW
---
3000
mW
Compliance to EN 55022,class A and FCC part 15,class A
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2012/07/03 REV:0 Page 1 of 4