FEATURES
►Industrial Standard SIP-7 Package
►Semi-regulated Output Voltage
►Very High Efficiency up to 89%
►High I/O Isolation 1000VDC
►Operating Ambient Temp. Range -40℃ to +95℃
►UL/cUL/IEC/EN 60950-1 Safety Approval
MA03 SERIES
DC/DC CONVERTER 3W, SIP-Package
PRODUCT OVERVIEW
The MINMAX MA03 series is a new range of isolated 3W DC/DC-converter modules in a small SIP-package. There are 12 models available with 5V, 12V or
24VDC input. These products have a typical load regulation of 5.0% to 7.0% depending on model.
The MA03 DC/DC converters are a compromise between a more expensive fully regulated converter and a non-regulated converter. They offer the
designer a new solution for many cost critical applications where the output voltage variation has to be kept in a certain limit under all load conditions.
Model Selection Guide
Model
Input
Number
Voltage
(Range)
MA03-05S05
MA03-05S09
MA03-05S12
MA03-05S15
MA03-12S05
MA03-12S09
MA03-12S12
MA03-12S15
MA03-24S05
MA03-24S09
MA03-24S12
MA03-24S15
VDC
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
Output
Voltage
VDC
5
9
12
15
5
9
12
15
5
9
12
15
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Input Voltage Range
Input Filter
Output Specifications
Parameter
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Output Current
Max.
Min.
mA
mA
600
12
333
6
250
4.5
200
3
600
12
333
6
250
4.5
200
3
600
12
333
6
250
4.5
200
3
Input Current
@Max. Load
mA(typ.)
723
689
701
686
298
285
284
281
152
147
146
147
@No Load
mA(typ.)
50
40
30
Load
Regulation
% (max.)
8
7
7
6
6
5
4.5
4
5.8
4.8
4.3
3.5
Max. capacitive
Load
μF
220
220
220
Efficiency
(typ.)
@Max. Load
%
83
87
85.5
87.5
84
87.5
88
89
82
85
85.5
85
Model
5V Input Models
12V Input Models
24V Input Models
5V Input Models
12V Input Models
24V Input Models
All Models
Min.
Typ.
Max.
Unit
-0.7
---
9
-0.7
---
18
-0.7
---
30
VDC
4.5
5
5.5
10.8
12
13.2
21.6
24
26.4
Internal Capacitor
Conditions
For Vin Change of 1%
Io=20% to 100%
0-20 MHz Bandwidth
Min.
Typ.
Max.
---
±1.01
±1.2
See Model Selection Guide
---
---
100
---
±0.01
±0.02
0.5 Second Max., Automatic Recovery
Unit
%
mV P-P
%/℃
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/07/31 REV:6 Page 1 of 4