English
Language : 

ADF-07_16 Datasheet, PDF (1/3 Pages) Minmax Technology Co., Ltd. – AC/DC Power Module 7W
ADF-07 SERIES
AC/DC Power Module 7W
FEATURES
►Fully Encapsulated Plastic Case for PCB Mounting
►Universal Input 85~264VAC, 47~440Hz
►Protection Class II as per IEC/EN 60536
►I/O Isolation 3000VAC with Reinforced Insulation
►Operating Ambient Temp. Range -25℃ to +70℃
►Overload/Voltage and Short Circuit Protection
►Designed-in EMI Emission meets EN55011/22 Class B & FCC Level B
►Designed-in EMC Immunity meets EN61000-4-2,3,4,5,6,8,11
►Eco Design, Compliant to Energy Star Specification and
ErP Directive 2009/125/EC
►UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking
PRODUCT OVERVIEW
The MINMAX ADF-07 series is a new range of fully encapsulated AC/DC power supply modules. They are designed for direct PCB mounting with solder
pins. The product features EMI-filter to EN55022, class B and EMS compliance to the EN 61000-4 standard. Universal input voltage 85-264VAC and
International safety approvals qualifies these power modules for applications in products with worldwide markets.
The ADF-07 series provide a cost effective solution for many space critical applications in commercial and industrial electronic equipment.
Model Selection Guide
Model
Number
ADF-07S03
ADF-07S05
ADF-07S12
ADF-07S15
ADF-07S24
Output
Voltage
VDC
3.3
5
12
15
24
Output Current
Max.
mA
1400
1400
583
466
291
Input Current
115VAC, 60Hz
@Max. Load
mA(typ.)
96
139
130
130
130
Max. capacitive
Load
μF
2200
2200
1000
1000
680
Efficiency
(typ.)
@Max. Load
%
70
73
78
78
78
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Input Voltage Range
No-Load Power Consumption
Inrush Current
External Fuse (Recommended)
Model
All Models
115VAC
230VAC
Cold Start at 25℃
All Models
Min.
Typ.
Max.
Unit
85
---
264
VAC
47
---
440
Hz
120
---
370
VDC
---
---
0.3
W
---
---
10
A
---
---
20
A
1.5A Slow – Blow Type
Output Specifications
Parameter
Output Voltage Setting Accuracy
Line Regulation
Load Regulation
Ripple & Noise
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Conditions
Min.
---
Vin=Min. to Max. @Full Load
---
Io=Min. to Max.
---
0-20 MHz Bandwidth
3.3 & 5.0VDC Output Models
Other Output Models
---
---
---
Zener diode clamp
---
---
---
Foldback, auto-recovery
(long term overload condition may cause damage)
105
Hiccup mode, Automatic Recovery
Typ.
±1.0
±0.5
±0.5
1.5
0.8
10
120
±0.01
---
---
Max.
±2.0
±1.0
±1.0
1.8
1.0
---
---
±0.02
5
---
Unit
%Vnom.
%
%
%VPP of Vo
%VPP of Vo
%Inom.
% of Vo
%/℃
% Vout
%Inom.
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2016/08/30 REV:17 Page 1 of 3