English
Language : 

DAT-31-PN Datasheet, PDF (10/12 Pages) Mini-Circuits – Digital Step Attenuator DC-2400 MHz
Digital Step Attenuator
DAT-31-PN+
DAT-31-PN
Pin 20 must always be low to prevent the attenuator from entering an unknown state.
Power-up Control Settings
The DAT-31-PN always assumes a specifiable attenuation setting on power-up, allowing a known attenua-
tion state to be established before an initial parallel control word is provided.
When the attenuator powers up with LE=0, the control bits are automatically set to one of four possible val-
ues .These four values are selected by the two power-up control bits,PUP1 and PUP2 ,as shown in Table 3:
(Power-Up Truth Table, Parallel Mode).
Table 3. Power-Up Truth Table, Parallel Mode
Attenuation State
PUP1
PUP2
LE
Reference
0
0
0
8 (dB)
0
1
0
16 (dB)
1
0
0
31 (dB)
1
1
0
Defined by C1-C16
(See Table 1-Truth Table)
X (Note 1)
X (Note 1)
1
Note 1: PUP1 and PUP2 Connection may be 0, 1, GROUND, or not con-
nect, without effect on attenuation state.
Power-Up with LE=1 provides normal parallel operation with C1-C16, and PUP1 and PUP2 are not active.
   

    
 
'.  )''#$/&-')#     .    ')+"$()')%&*(**!'(("& '&$"&*"&""),"+*-*"+
      
     

Page 10 of 12