XU1012-QH Datasheet, PDF (1/7 Pages) Mimix Broadband – 5.6-10.5 GHz Up-Converter
5.6-10.5 GHz Up-Converter
QFN, 4x4mm
February 2010 - Rev 18-Feb-10
Features
Optimized for LSB Operation
8 dB Conversion Gain
25 dBm OIP3
25 dBc LO Suppression Typical
15 dB Linear Gain Control
4x4mm QFN Package
General Description
Mimix Broadband’s 5.6-10.5 GHz GaAs MMIC integrated
up-converter has a typical LSB conversion gain of 8 dB,
and an image rejection of 15 dBc. The device includes an
LO Buffer amplifier, double balanced image reject mixer,
RF buffer amplifier and variable attenuator. Variable gain
regulation can be achieved through bias adjustment
with turn-down trajectories optimized to maintain
linearity and minimal LO leakage. The device comes in a
an RoHS compliant 4x4mm QFN surface mount package
offering excellent RF and thermal properties. Typical
applications for this device are as an up-converter stage
in linear C-Band radio transmit lineups. The device is well
suited for Millimeter-wave Point-to-Point Radio, LMDS,
SATCOM and VSAT applications.
Bias Requirements
Parameter
Drain Bias Voltage LO Buffer (Vd1)
Drain Bias Voltage RF Amp Stage 1 (Vd2)
Drain Bias Voltage RF Amp Stage 2,3 (Vd3)
Gate Bias Voltage LO Buffer (Vg1)
Gate Bias Voltage RF Amp Stage 1 (Vg2)
Gate Bias Voltage RF Amp Stage 2,3 (Vg3)
Variable Attenuator Control (Vc)
Supply Current LO Buffer (Id1)
Supply Current RF Amp Stage 1 (Id2)
Supply Current RF Amp Stage 2,3 (Id3)
U1012-QH
Absolute Maximum Ratings1
Supply Voltage (Vd)
+7V
Gate Bias Voltage (Vg)
-3.0<Vg<0V
Supply Current (LO Buffer)
150 mA
Supply Current (RF Buffer)
150 mA
IF Input Power (IFin)
+15 dBm
LO Input Power (LOin)
+15 dBm
Storage Temperature (Tstg)
-65 to +165 ºC
Operating Temperature (Ta)
-40 to +85 ºC
Abs. Max. Junction/Channel Temp. 150 ºC
Continuous Power Dissipation (Pdiss) at 80 ºC 1.5W
Thermal Resistance (Tchannel=150 ºC) 50 ºC/W
Mouting Temperature
See solder reflow profile
ESD Min. - Machine Model (MM) Class A
ESD Min. - Human Body Model (HBM) Class 1A
MSL Level
3
(1) Operation of this device above any one of these parameters may
cause permanent damage.
(2) Channel temperature directly affects a device’s MTTF. Channel
temperature should be kept as low as possible to maximize lifetime.
Units Min. Typ. Max.
VDC
+5.0
VDC
+5.0
VDC
+5.0
VDC
-1.0
VDC
-1.0
VDC
-1.0
VDC
-2.5
-
0.0
mA
80
mA
60
mA
20
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 1 of 7
Characteristic Data and Specifications are subject to change without notice. ©2010 Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.