English
Language : 

XU1006-QB_07 Datasheet, PDF (1/9 Pages) Mimix Broadband – 36.0-42.0 GHz GaAs Transmitter SMT, 7x7 mm
36.0-42.0 GHz GaAs Transmitter
SMT, 7x7 mm
December 2007 - Rev 18-Dec-07
Features
Sub-harmonic, Image Reject Transmitter
Integrated Mixer, LO Doubler/Buffer & Output Amplifier
+17.0 dBm Output Third Order Intercept (OIP3)
+2.0 dBm LO Drive Level
5.0 dB Conversion Gain
7x7mm SMT Package
100% RF and DC Testing
U1006-QB
General Description
Absolute Maximum Ratings
Mimix Broadband’s 36.0-42.0 GHz GaAs transmitter has a +17.0 dBm
output third order intercept across the band. This device is a
balanced, resistive pHEMT mixer followed by a distributed output
amplifier and includes an integrated LO doubler and LO buffer
amplifier. The use of integrated LO doubler and LO buffer amplifier
makes the provision of the LO easier than for fundamental mixers at
Supply Voltage (Vd)
Supply Current (Id)
Gate Bias Voltage (Vg)
Input Power (Pin)
Storage Temperature (Tstg)
+6.0 VDC
350 mA
+0.3 VDC
+0.0 dBm
-65 to +165 deg C
these frequencies. I and Q mixer inputs are provided and an external
Operating Temperature (Ta) -55 to MTTF Table1
90 degree hybrid is required to select the desired sideband. The
Channel Temperature (Tch) MTTF Table1
device comes in a 7x7mm SMT package that is RoHS compliant.This
device is well suited for Millimeter-wave Point-to-Point Radio, LMDS,
SATCOM and VSAT applications.
ESD - Human Body Model Class 1A
ESD - Machine Body Model Class M1
(1) Channel temperature affects a device’s MTTF. It is
recommended to keep channel temperature as low as
possible for maximum life
Electrical Characteristics (Ambient Temperature T = 25o C)
Parameter
Units Min. Typ. Max.
Frequency Range (RF) Upper Side Band
GHz
36.0
-
42.0
Frequency Range (RF) Lower Side Band
GHz
36.0
-
42.0
Frequency Range (LO)
GHz
16.0
-
26.0
Frequency Range (IF)
GHz
DC
-
4.0
Output Return Loss RF (S22)
dB
-
10.0
-
Small Signal Conversion Gain IF/RF (S21)
dB
2.0
5.0
7.0
LO Input Drive (PLO)
dBm +2.0 +4.0
-
Leakage @ RF Port LOx1
dBm
-
-25.0
-
Leakage @ RF Port LOx2
dBm
-
-15.0 -12.0
Input Third Order Intercept (IIP3)
dBm 10.0 13.0
-
Attenuation Range
dB
25.0 28.0
-
Drain Bias Voltage (Vd)
VDC
-
+4.0
-
Gate Bias Voltage (Vg1)
VDC
-
-0.4
-
Gate Bias Voltage (Vg2) Mixer, Doubler
VDC
-
-0.5
-
Dynamic Range Control (Vc)
VDC
-2.0
-
0.0
Supply Current (Id) (Vd=4.0V)
mA
-
240
-
Supply Current (Ic)
mA
-
0.0
-
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 1 of 9
Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.