English
Language : 

CMM6003-SC_07 Datasheet, PDF (1/5 Pages) Mimix Broadband – 50-900 MHz High Dynamic Range Amplifier
50-900 MHz
High Dynamic Range Amplifier
August 2007 - Rev 07-Aug-07
CMM6003-SC
Features
50 to 900 MHz Frequency Range
+41 dBm Output IP3
-71 dBc CTB
-48 dBc CSO
1.6 dB Noise Figure (@ 450 MHz)
17 dB Gain
22 dBm P1dB
RoHS Compliant SOT-89 SMT Package
Single Power Supply
+3V to +5V Voltage Rail
MTBF > 100 Years
Ideal for CATV Applications
Description
The CMM6003-SC is a high dynamic range amplifier suitable
for cable TV applications between 50 and 900 MHz. The
combination of gain flatness, bandwidth, low noise figure and
high third order intercept point make it ideal for cable modem,
CATV distribution and laser diode driver applications. The
CMM6003-SC can operate directly from 5V or 3.3V supply
voltage in 75 ohm systems. The device is manufactured using
a highly reliable GaAs MESFET technology with an MTBF of
over 100 years at a mounting temperature of +85ºC. All
devices are 100% RF (at 800Mhz) and DC tested and they
come in an RoHs compliant SOT-89 package which provides
excellent electrical stability and low thermal resistance.
Absolute Maximum Ratings
Supply Voltage
+6.0 V
RF Input Power*
+10 dBm
Storage Temperature
-55ºC to 150ºC
Junction Temperature
150ºC
Operating Temperature
-40ºC to +85ºC
Thermal Resistance
59º C/W
Operation of this device above any of these parameters may cause damage.
*Operation with more than 10 dBm of input power may cause 2 dB
degradation in OIP3 performance.
Electrical Characteristics
Unless otherwise specified, the following specifications are guaranteed at room temperature
in a Mimix test fixture.
Parameter
Condition
Min Typ Max Units
Frequency R ange
Gain
Externally matched
Input Return Loss
Externally matched
Output IP3
Noise Figure
@ 50 MHz
Noise Figure
@ 800 MHz
Output P1dB
Operating Current Range
Supply Voltage
50 800 900 MHz
15 17 18 dB
-11
dB
+41
dB m
3.3
dB
1.9
dB
22
dBm
120 150 180 mA
5.0
V
Notes:
1. T = 25°C, Vdd = 5.0, Frequency = 800 MHz, 50 Ohm system
2. OIP3 measured with two tones at output power of 5 dBm/tone separated by 10 MHz.
Typical Parameters
Parameter
Typical
Units
Frequency Range 100 450 900 MHz
Gain
17.5 17.2 16.3 dB
Input Return Loss -12 -12 -11 dB
Output Return Loss -16 -16 -13
dB
Output P1dB
Output IP3
23 23.6 23.8
40 39
37
dBm
dBm
Output IP2
52 52 52 dBm
Noise Figure
CTB
3.5 1.6 2
dB
-72
dBc
CSO
-48
dBc
Xmod
-65
dBc
Supply Voltage
5
5
5
V
Current
150 150 150 mA
Notes:
1. Typical values reflect performance in recommended application circuit.
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 1 of 5
Characteristic Data and Specifications are subject to change without notice. ©2007 Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.