PLAD30KP10 Datasheet, PDF (3/5 Pages) Microsemi Corporation – 30kW Surface Mount Transient Voltage Suppressor
SCOTTSDALE DIVISION
PLAD30KP10 thru PLAD30KP400CA, e3
30kW Surface Mount Transient
Voltage Suppressor
MICROSEMI
PART NUMBER
(Note 2)
REVERSE
STAND-
OFF
VOLTAGE
VWM
(Note 1)
BREAKDOWN
VOLTAGE
V(BR)
MAXIMUM
CLAMPING
VOLTAGE
VC
@ IPP
MAXIMUM
STANDBY
CURRENT
ID
@ VWM
MAXIMUM
PEAK PULSE
CURRENT
IPP (FIG. 3)
MAXIMUM
TEMPERATURE
COEFFICIENT
OF V(BR)
V(BR)
@
I(BR)
VOLTS
VOLTS
VOLTS
mA
μA
αV(BR)
A
mV/ ºC
PLAD30KP70
70
77.8 – 95.1
5
125
10
240
93
PLAD30KP70A
70
77.8 – 86.0
5
113
10
264
84
PLAD30KP75
75
83.3 – 102.0
5
134
10
222
100
PLAD30KP75A
75
83.3 – 92.1
5
121
10
246
90
PLAD30KP78
78
86.7 – 106.0
5
139
10
216
104
PLAD30KP78A
78
86.7 – 95.8
5
126
10
240
95
PLAD30KP85
85
94.4 – 115.0
5
151
10
198
115
PLAD30KP85A
85
94.4 – 104.0
5
137
10
216
104
PLAD30KP90
90
100 – 122
5
160
10
186
120
PLAD30KP90A
90
100 – 111
5
146
10
204
109
PLAD30KP100
100
111 – 136
5
179
10
168
134
PLAD30KP100A
100
111 – 123
5
162
10
186
122
PLAD30KP110
110
122 – 149
5
196
10
156
147
PLAD30KP110A
110
122 – 135
5
177
10
168
132
PLAD30KP120
120
133 – 163
5
214
10
140
161
PLAD30KP120A
120
133 – 147
5
193
10
156
145
PLAD30KP130
130
144 – 176
5
231
10
130
174
PLAD30KP130A
130
144 – 159
5
209
10
142
157
PLAD30KP150
150
167 – 204
5
268
10
112
202
PLAD30KP150A
150
167 – 185
5
243
10
124
183
PLAD30KP160
160
178 – 218
5
287
10
104
216
PLAD30KP160A
160
178 – 197
5
259
10
116
195
PLAD30KP170
170
189 – 231
5
304
10
98
229
PLAD30KP170A
170
189 – 209
5
275
10
110
207
PLAD30KP180
180
200 – 244
5
321
10
94
242
PLAD30KP180A
180
200 – 221
5
291
10
104
219
PLAD30KP200
200
222 – 271
5
356
10
84
269
PLAD30KP200A
200
222 – 245
5
322
10
94
243
PLAD30KP220
220
245 – 299
5
293
10
76
297
PLAD30KP220A
220
245 – 271
5
356
10
84
269
PLAD30KP250
250
278 – 308
5
403
10
74
306
PLAD30KP260A
260
289 – 320
5
419
10
71
318
PLAD30KP280A
280
311 – 345
5
451
10
66
344
PLAD30KP300A
300
333 – 369
5
483
10
62
368
PLAD30KP350A
350
389 – 431
5
564
10
53
430
PLAD30KP400A
400
444 - 492
5
644
10
46
490
NOTE 1: Transient Voltage Suppressors are normally selected with reverse “Stand Off Voltage” VWM which should
be equal to or greater than the dc or continuous peak operating voltage level.
NOTE 2: For bidirectional construction, indicate a C or CA suffix after the part number.
Symbol
VWM
PPP
V(BR)
ID
SYMBOLS & DEFINITIONS
Definition
Working Peak (Standoff) Voltage
Peak Pulse Power
Breakdown Voltage
Standby Current
Symbol
IPP
VC
I(BR)
Definition
Peak Pulse Current
Clamping Voltage
Breakdown Current for V(BR)
Copyright © 2007
9-12-2007 Rev G
Microsemi
Scottsdale Division
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503
Page 3