English
Language : 

M1.5KE6.8A Datasheet, PDF (3/4 Pages) Microsemi Corporation – Unidirectional and Bidirectional Transient Voltage Suppressor
Gort Road Business Park, Ennis, Co. Clare, Ireland.
Tel: +353 (0) 65 6840044, Fax: +353 (0) 65 6822298
TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841
Tel: 1-800-446-1158 / (978) 794-1666, Fax: (978) 6890803
Website: http://www.microsemi.com
___________________________________________________________________________________________________________________________________
ELECTRICAL CHARACTERISTICS @ 25oC
Industry Type
Number
(Note 2)
JEDEC
Type
Number
M1.5KE6.8A
M1.5KE7.5A
M1.5KE8.2A
M1.5KE9.1A
M1.5KE10A
M1.5KE11A
M1.5KE12A
M1.5KE13A
M1.5KE15A
M1.5KE16A
M1.5KE18A
M1.5KE20A
M1.5KE22A
M1.5KE24A
M1.5KE27A
M1.5KE30A
M1.5KE33A
M1.5KE36A
M1.5KE39A
M1.5KE43A
M1.5KE47A
M1.5KE51A
M1.5KE56A
M1.5KE62A
M1.5KE68A
M1.5KE75A
M1.5KE82A
M1.5KE91A
M1.5KE100A
M1.5KE110A
M1.5KE120A
M1.5KE130A
M1.5KE150A
M1.5KE160A
M1.5KE170A
M1.5KE180A
M1.5KE200A
M1.5KE220A
M1.5KE250A
M1.5KE300A
M1.5KE350A
M1.5KE400A
1N6267A
1N6268A
1N6269A
1N6270A
1N6271A
1N6272A
1N6273A
1N6274A
1N6275A
1N6276A
1N6277A
1N6278A
1N6279A
1N6280A
1N6281A
1N6282A
1N6283A
1N6284A
1N6285A
1N6286A
1N6287A
1N6288A
1N6289A
1N6290A
1N6291A
1N6292A
1N6293A
1N6294A
1N6295A
1N6296A
1N6297A
1N6298A
1N6299A
1N6300A
1N6301A
1N6303A
-
-
-
Rated
Standoff
Voltage
VWM
(Note 1)
V
5.80
6.40
7.02
7.78
8.55
9.40
10.220
11.10
12.80
13.60
15.30
17.10
18.80
20.50
23.10
25.60
28.20
30.80
33.30
36.80
40.20
43.60
47.80
53.00
58.10
64.10
70.10
77.80
85.50
94.00
102.00
111.00
128.00
136.00
145.00
154.00
171.00
185.00
214.00
256.00
300.00
324.00
Breakdown
Voltage
VBR @ IBR
V
mA
6.45 – 7.14
10
7.13 – 7.88
10
7.79 – 8.61
10
8.65 – 9.55
1
9.50 – 10.50
1
10.50 – 11.60
1
11.40 – 12.60
1
12.40 – 13.70
1
14.30 – 15.80
1
15.20 – 16.80
1
17.10 – 18.90
1
19.00 – 21.00
1
20.90 – 23.10
1
22.80 – 25.20
1
25.70 – 28.40
1
28.50 – 31.50
1
31.40 – 34.70
1
34.20 – 37.80
1
37.10 – 41.00
1
40.90 – 45.20
1
44.70 – 49.40
1
48.50 – 53.60
1
53.20 – 58.80
1
58.90 – 65.10
1
64.60 – 71.40
1
71.30 – 78.80
1
77.90 – 86.10
1
86.50 – 95.50
1
95.00 – 105.00
1
105.00 – 116.00
1
114.00 – 126.00
1
124.00 – 137.00
1
143.00 – 158.00
1
152.00 – 168.00
1
162.00 – 179.00
1
171.00 – 189.00
1
190.00 – 210.00
1
209.00 – 231.00
1
237.00 – 263.00
1
285.00 – 315.00
1
332.00 – 368.00
1
380.00 – 420.00
1
Maximum
Clamping
Voltage
VC @ IPP
V
10.5
11.3
12.1
13.4
14.5
15.6
16.7
18.2
21.2
22.5
25.2
27.7
30.6
33.2
37.5
41.4
45.7
49.9
53.9
59.3
64.8
70.1
77.0
85.0
92.0
103.0
113.0
125.0
137.0
152.0
165.0
179.0
207.0
219.0
234.0
246.0
274.0
328.0
344.0
414.0
482.0
548.0
Maximum
Standby
Current
ID @ VWM
A
1000
500
200
50
10
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Peak Pulse
Current
(see Fig. 2)
IPP
A
143.0
132.0
124.0
112.0
103.0
96.0
90.0
82.0
71.0
67.0
59.5
54.0
49.0
45.0
40.0
36.0
33.0
30.0
28.0
25.3
23.2
21.4
19.5
17.7
16.3
14.6
13.3
12.0
11.0
9.9
9.1
8.4
7.2
6.8
6.4
6.1
5.5
4.6
5.0
5.0
4.0
4.0
Maximum
Temperature
Coefficient of
VBR
(V(BR))
%/oC
.057
.061
.065
.068
.073
.075
.078
.081
.084
.086
.088
.090
.092
.094
.096
.097
.098
.099
.100
.101
.101
.102
.103
.104
.104
.105
.105
.106
.106
.107
.107
.107
.108
.108
.108
.108
.108
.110
.110
.111
.111
.111
NOTE 1:
NOTE 2:
NOTE 3:
Normal selection criteria for TVS devices is by rated stand-off voltage (VWM) and should be equal or greater than dc
or continuous peak operating voltage.
For bidirectional construction, indicate a CA as suffix after part number (e.g. M1.5KE33CA). For Bidirectional types
having VWM of 8 volts and under, the ID leakage current is doubled. Bidirectional capacitance is half that shown in
Figure 4 at zero volts.
For unidirectional, the forward voltage (VF) is 3.5 volts maximum at 100 Amps peak for 8.3 ms half-sine wave.
RF01008 Rev C, September 2010
High Reliability Product Group
Page 3 of 4