JANTX1N3893 Datasheet, PDF (3/7 Pages) Microsemi Corporation – FAST RECOVERY RECTIFIERS Qualified per MIL-PRF-19500/304
1N3889 – 1N3891, 1N3893
Symbol
CJ
IF(AV)
IFSM
IRM
trr
VFM
VRRM
VRWM
SYMBOLS & DEFINITIONS
Definition
Junction Capacitance: The junction capacitance in pF at a specified frequency.
Average Forward Current: The average forward current dc value, no alternating component.
Maximum Forward Surge Current: The forward current, surge peak or rated forward surge current.
Maximum Reverse Current: The maximum reverse (leakage) current that will flow at the specified voltage and
temperature.
Reverse Recovery Time: The time interval between the instant the current passes through zero when changing from
the forward direction to the reverse direction and a specified decay point after a peak reverse current occurs.
Maximum Forward Voltage: The maximum forward voltage the device will exhibit at a specified current.
Repetitive Peak Reverse Voltage: The peak reverse voltage including all repetitive transient voltages but excluding all
non-repetitive transient voltages.
Working Peak Reverse Voltage: The maximum peak voltage that can be applied over the operating temperature range
excluding all transient voltages (ref JESD282-B). Also sometimes known as PIV.
ELECTRICAL CHARACTERISTICS @ TA = 25 ºC unless otherwise noted
Type
1N3889(R)
Typical
Junction
Capacitance
CJ
115 pF (1)
Average
Forward
Current
IF(AV)
TC = 100 ºC
12 A
Maximum
Forward
Voltage
VFM
TC = 25 oC
1.5 V
@
IFM = 20 A (2)
Maximum
Reverse
Current
IRM
TC = 25 oC TC = 150 oC
10 µA
@
VRRM
2 mA
@
VRRM
NOTES: 1. VR = 10 V, f = 1 Mhz, TJ = 25 ºC.
2. IFM = 38 A, TJ = 25 ºC. Pulse test: pulse width 300 µsec, duty cycle 2%.
3. IF = 1 A, VR = 30 A, di/dt = 25 A/µs, TC = 55 ºC.
Maximum
Reverse
Recovery
Time
trr
200 ns (3)
Parameters / Test Conditions
Forward Voltage
IFM = 38 A, TC = 25 °C*
Forward Voltage
IFM = 250 A, TC = 150 °C**
Reverse Current
VRM = 100 V, TC = 25 °C
VRM = 200 V, TC = 25 °C
VRM = 400 V, TC= 25 °C
Reverse Current
VRM = 100 V, TC = 150 °C
VRM = 200 V, TC = 150 °C
VRM = 400 V, TC = 150 °C
Reverse Recovery Time
VRM = 30 V, IF = 1A, TC = 55 °C*
1N3890 / A / R / AR
1N3891 / A / R / AR
1N3893 / A / R / AR
1N3890 / A / R / AR
1N3891 / A / R / AR
1N3893 / A / R / AR
1N3890, 1N3891, 1N3893
1N3890A, 1N3891A,1N3893A / AR
* Pulse test: Pulse width 300 µsec, duty cycle 2%.
** Pulse test: Pulse width 800 µsec.
Symbol
VFM
VFM
IRM
IRM
Trr
Min.
Max.
1.5
2.75
10
2
200
150
Unit
V
V
µA
mA
ns
T4-LDS-0143, Rev. 2 (120861)
©2012 Microsemi Corporation