DYNAMIC CHARACTERISTICS
APT5016BFLL_SFLL
Symbol Characteristic
Test Conditions
Ciss
Coss
Crss
Qg
Qgs
Qgd
td(on)
tr
td(off)
tf
Eon
Eoff
Eon
Eoff
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge 3
Gate-Source Charge
Gate-Drain ("Miller") Charge
Turn-on Delay Time
Rise Time
Turn-off Delay Time
Fall Time
Turn-on Switching Energy 6
Turn-off Switching Energy
Turn-on Switching Energy 6
Turn-off Switching Energy
VGS = 0V
VDS = 25V
f = 1 MHz
VGS = 10V
VDD = 250V
ID = 30A @ 25°C
RESISTIVE SWITCHING
VGS = 15V
VDD = 250V
ID = 30A @ 25°C
RG = 1.6Ω
INDUCTIVE SWITCHING @ 25°C
VDD = 333V, VGS = 15V
ID = 30A, RG = 5Ω
INDUCTIVE SWITCHING @ 125°C
VDD = 333V VGS = 15V
ID = 30A, RG = 5Ω
SOURCE-DRAIN DIODE RATINGS AND CHARACTERISTICS
Symbol Characteristic / Test Conditions
IS
Continuous Source Current (Body Diode)
ISM Pulsed Source Current 1 (Body Diode)
VSD Diode Forward Voltage 2 (VGS = 0V, IS = -30A)
dv/dt
Peak Diode Recovery dv/dt 5
trr
Reverse Recovery Time
(IS = -30A, di/dt = 100A/µs)
Tj = 25°C
Tj = 125°C
Reverse Recovery Charge
Qrr
(IS = -30A, di/dt = 100A/µs)
Tj = 25°C
Tj = 125°C
Peak Recovery Current
IRRM
(IS = -30A, di/dt = 100A/µs)
Tj = 25°C
Tj = 125°C
MIN
MIN
TYP
2833
600
60
72
16
42
10
10
27
14
256
172
476
215
MAX
UNIT
pF
nC
ns
µJ
TYP MAX UNIT
30 Amps
120
1.3 Volts
15 V/ns
250
ns
500
1.3
µC
4.5
12
Amps
18
THERMAL CHARACTERISTICS
Symbol Characteristic
MIN TYP MAX UNIT
RθJC
RθJA
Junction to Case
Junction to Ambient
0.38
40
°C/W
1 Repetitive Rating: Pulse width limited by maximum junction
temperature
2 Pulse Test: Pulse width < 380 µs, Duty Cycle < 2%
3 See MIL-STD-750 Method 3471
4 Starting Tj = +25°C, L = 2.89mH, RG = 25Ω, Peak IL = 30A
5 dv/dt numbers reflect the limitations of the test circuit rather than the
device itself. IS ≤ -ID30A di/dt ≤ 700A/µs VR ≤ 500 TJ ≤ 150°C
6 Eon includes diode reverse recovery. See figures 18, 20.
APT Reserves the right to change, without notice, the specifications and information contained herein.
0.40
0.35
0.9
0.30
0.7
0.25
0.20
0.15
0.10
0.05
0
10-5
0.5
Note:
0.3
t1
0.1
0.05
SINGLE PULSE
t2
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION