English
Language : 

3PMT5 Datasheet, PDF (2/3 Pages) Microsemi Corporation – POWERMITE Low Profile 1500 Watt Transient Voltage Suppressor
SCOTTSDALE DIVISION
3PMT5.0A thru 3PMT170A
POWERMITE®
Low Profile 1500 Watt
Transient Voltage Suppressor
MICROSEMI
PART NUMBER
STANDOFF
VOLTAGE
VWM
VOLTS
BREAKDOWN
VOLTAGE
VBR
@1 mA
VOLTS
MIN
CLAMPING
VOLTAGE
VC
@ IPP
(FIGURE 4)
VOLTS
MAX
PEAK PULSE
CURRENT
IPP
(FIGURE 4)
AMPS
STANDBY
CURRENT
ID
@ VWM
µA
MAX
3PMT13A
13
14.4
21.5
69.7
5
3PMT14A
14
15.8
23.2
64.7
5
3PMT15A
15
16.7
24.4
61.5
5
3PMT16A
16
17.8
26.0
57.7
5
3PMT17A
17
18.9
27.6
53.3
5
3PMT18A
18
20.0
29.2
51.4
5
3PMT20A
20
22.2
32.4
46.3
5
3PMT22A
22
24.4
35.5
42.2
5
3PMT24A
24
26.7
38.9
38.6
5
3PMT26A
26
28.9
42.1
35.6
5
3PMT28A
28
31.1
45.4
33.0
5
3PMT30A
30
33.3
48.4
31.0
5
3PMT33A
33
36.7
53.3
28.1
5
3PMT36A
36
40.0
58.1
25.8
5
3PMT40A
40
44.4
64.5
23.2
5
3PMT43A
43
47.8
69.4
21.6
5
3PMT45A
45
50.0
72.7
20.6
5
3PMT48A
48
53.3
77.4
19.4
5
3PMT51A
51
56.7
82.4
18.2
5
3PMT54A
54
60.0
87.1
17.2
5
3PMT58A
58
64.4
93.6
16.0
5
3PMT60A
60
66.7
96.8
15.5
5
3PMT64A
64
71.1
103.0
14.6
5
3PMT70A
70
77.8
113
13.3
5
3PMT75A
75
83.3
121
12.4
5
3PMT78A
78
86.7
126
11.4
5
3PMT85A
85
94.4
137
10.4
5
3PMT90A
90
100
146
10.3
5
3PMT100A
100
111
162
9.3
5
3PMT110A
110
122
177
8.4
5
3PMT120A
120
133
193
7.8
5
3PMT130A
130
144
209
7.2
5
3PMT150A
150
167
243
6.2
5
3PMT160A
160
178
259
5.8
5
3PMT170A
170
189
275
5.5
5
For bi-directional indicate a C suffix after the part number (i.e.: 3PMT170CA). Capacitance will be ½ that shown in figure 3.
Part numbers in italics are preferred devices.
TEMPERATURE
COEFFICIENT
OF VBR
αV(BR)
%/°C
MAX
.084
.086
.087
.088
.090
.092
.093
.094
.096
.097
.098
.099
.100
.101
.101
.102
.102
.103
.103
.104
.104
.104
.105
.105
.105
.106
.106
.107
.107
.107
.107
.108
.108
.108
.108
Symbol
VRWM
VBR
VC
ID
SYMBOLS & DEFINITIONS
Definition
Working Peak Reverse Voltage: The maximum peak voltage that can be applied over the operating
temperature range.
Minimum Breakdown Voltage: The minimum voltage the device will exhibit at a specified current.
Minimum Clamping Voltage: The maximum voltage the device will exhibit at the peak pulse current.
Maximum Leakage Current: The maximum leakage current that will flow at the specified voltage and
temperature.
Copyright  2003
12-6-2002 REV A
Microsemi
Scottsdale Division
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503
Page 2