English
Language : 

PD69012 Datasheet, PDF (11/18 Pages) Microsemi Corporation – 12 Ports Power Over Ethernet Manager
PD69012 - 12 Ports Power Over Ethernet Manager
AT PORTS PARAMETERS
PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
Automatic recovery from
overload shutdown
TOVLREC value, measured from port shutdown
(can be modified through control port)
5
s
Automatic recovery from no-load TUDLREC value, measured from port shutdown
shutdown
(can be modified through control port)
1
s
Cutoff timers accuracy
Typical accuracy of Tcut
4
2
0
ms
Inrush current
IInrsh
For t=50 ms, Cload=180 uF max.
400
Output current operating range Iport
Continuous operation after startup period.
10
450 mA
643 mA
Output power available,
operating range
Pport
Continuous operation after startup period,
at port output.
0.57
36
W
Off mode current
Imin1
Must disconnect for t greater than TUVL
0
5
mA
Imin2
May or may not disconnect for t greater
than TUVL
5
7.5
10
mA
PD power maintenance request
drop-out time limit
TPMDO
Buffer period to handle transitions
300
400 ms
Over load current detection range Icut
Time limited to TOVL
686
728
771 mA
Over load time limit
TOVL
50
75
ms
Turn on rise time
Trise
From 10% to 90% of Vport
(Specified for PD load consisting of 100 uF capacitor
15
us
in parallel to 200 Ω).
Turn off time
Toff
From Vport to 2.8 Vdc
500 ms
Time Maintain Power Signature TMPS DC modulation time for dc disconnect
49
ms
AC disconnect impedance
Zac
27
600
2000 KΩ
Copyright © 2009
Rev. 1.0, 2009-03-03
Microsemi
Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, (ROW): (949) 221-7100 Fax: (949) 756-0308
Page 11