English
Language : 

A3P600L-FG484I Datasheet, PDF (103/242 Pages) Microsemi Corporation – Dramatic Reduction in Dynamic and Static Power Savings
ProASIC3L Low Power Flash FPGAs
3.3 V GTL+
Gunning Transceiver Logic Plus is a high-speed bus standard (JESD8-3). It provides a differential
amplifier input buffer and an open-drain output buffer. The VCCI pin should be connected to 3.3 V
Table 2-142 • Minimum and Maximum DC Input and Output Levels
3.3 V GTL+
VIL
VIH
VOL VOH IOL IOH IOSL IOSH IIL IIH
Drive
Strength
Min.
V
Max.
V
Min.
V
Max.
V
Max.
V
Min.
Max.
V mA mA mA1
Max.
mA1 µA2 µA2
35 mA
–0.3 VREF – 0.1 VREF + 0.1 3.6
0.6
– 35 35 268
181 10 10
Notes:
1. Currents are measured at 100°C junction temperature and maximum voltage.
2. Currents are measured at 85°C junction temperature.
VTT
GTL+ 25
Test Point
10 pF
Figure 2-15 • AC Loading
Table 2-143 • AC Waveforms, Measuring Points, and Capacitive Loads
Input Low (V)
Input High (V)
Measuring
Point* (V)
VREF (typ.) (V) VTT (typ.) (V)
VREF – 0.1
VREF + 0.1
1.0
1.0
1.5
Note: *Measuring point = Vtrip. See Table 2-16 on page 2-12 for a complete table of trip points.
CLOAD (pF)
10
Timing Characteristics
Table 2-144 • 3.3 V GTL+ – Applies to 1.5 V DC Core Voltage
Commercial-Case Conditions: TJ = 70°C, Worst-Case VCC = 1.425 V,
Worst-Case VCCI = 3.0 V VREF = 1.0 V
Applicable to Pro I/O Banks
Speed
Grade
Std.
tDOUT
0.59
tDP
1.85
tDIN
0.04
tPY
2.12
tEOUT
0.38
tZL
1.88
tZH
tLZ tHZ tZLS
1.85
3.90
tZHS
3.86
Units
ns
–1
0.50 1.57 0.03 1.80 0.33 1.60 1.57
3.31 3.29
ns
Note: For specific junction temperature and voltage supply levels, refer to Table 2-6 on page 2-7 for derating values.
Table 2-145 • 3.3 V GTL+ – Applies to 1.2 V DC Core Voltage
Commercial-Case Conditions: TJ = 70°C, Worst-Case VCC = 1.14 V,
Worst-Case VCCI = 3.0 V VREF = 1.0 V
Applicable to Pro I/O Banks
Speed
Grade
Std.
tDOUT
0.77
tDP
1.85
tDIN
0.05
tPY
2.12
tEOUT
0.50
tZL
1.88
tZH
tLZ tHZ tZLS
1.85
3.90
tZHS
3.86
Units
ns
–1
0.66 1.57 0.04 1.80 0.43 1.60 1.57
3.31 3.29
ns
Note: For specific junction temperature and voltage supply levels, refer to Table 2-6 on page 2-7 for derating values.
Revision 13