53254 Datasheet, PDF (2/4 Pages) Micropac Industries – 40VDC - 10A SOLID STATE RELAY
RECOMMENDED OPERATING CONDITIONS:
Parameter
Output Voltage
Continuous Output Current
Input Current (on)
Input Voltage (off)
Operating Case Temperature
53254
40VDC – 10A Solid State Relay
Symbol
VO (OFF)
IO (ON)
IF (ON)
VF (OFF)
TC
Min.
5
0
-40
Max.
40
10
15
1
85
Units
VDC
A
mA
VDC
°C
ELECTRICAL SPECIFICATIONS
TC= -40°C to +85°C unless otherwise specified
Parameter
Sym.
Output On-Resistance
Output Leakage Current
Input Forward Voltage
Input Reverse Breakdown Voltage
R (ON)
IO (OFF)
VF
VR
Input-Output Leakage
II-O
Turn-On Time
tON
Turn-Off time
tOFF
Rise Time
tR
Fall Time
tF
Thermal Resistance (junction-case)
θJC
* All typical values are at TC = 25°C
Min. Typ.*
 .025

<1
 3.75
6
40


 3.3
 0.35
 2.5
 .19
Max.
.050
250
4.20

1
8.0
3
6.0
2.0
Unit
s
Ω
µA
VDC
VDC
µA
ms
ms
ms
ms
Test Conditions
IF = 15 mA
IO = 1 A
VF = 1 VDC
VO = 45 VDC
IF = 15 mA
IR = 10 µA
RH ≤ 45%, t = 5 s
VI-O = 1000 VDC
TC = 25°C
IF = 15 mA
IO = 1 A
V load = 40 VDC
Pulse width = 10 ms
Duty cycle ≤ 1%
 1.8
 °C/W
Notes
4, 5
6
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281
www.micropac.com E-MAIL: hybridsales@micropac.com 05/16/01