52301 Datasheet, PDF (1/2 Pages) Micropac Industries – INSTRUMENTATION AMPLIFIER (PRELIMINARY)
52301 INSTRUMENTATION AMPLIFIER (PRELIMINARY)
Mii
HYBRID MICROELECTRONICS
PRODUCTS DIVISION
Features:
ƒ +25°C to +180°C Operation
• Ultra-Low Voltage Drift
• Low Offset Voltage
• Low Nonlinearity
• Low Noise
• High CMR
• High Input Impedance
Applications:
• Amplification of signals from sources such as:
Strain Gages
Thermocouplers
RTDs
• Low Level Signals
• Medical Instrumentation
DESCRIPTION
The MII 52301 is a high accuracy hybrid-circuit instrumentation amplifier designed for signal conditioning requirements where
very high performance is desired.
The input stage uses ultra-low drift, low noise technology to provide exceptional input characteristics.
PARAMETER
Gain Equation:
A, = 1 + 40K/Rg
+25°C
MIN
MAX
+180°C (1)
MIN
MAX
UNITS
Rated Output
Voltage
Current
Input Offset Voltage
(vs Temp, 30 µV/°C)
Input Bias Current
Each Input
Offset
(vs Temp, .3na/°C)
Input Voltage
Common Mode Voltage Range
CMRR: Gain = 100
Power Supply
Voltage
Current
Dynamic Response
Full power Bandwidth
Unity Gain Bandwidth
(-3dB)
±10
±10
10
5
±8
±16
10
50
10
50
±10
±10
60
40
±15
±15
15
20
40
35
.8
.8
V
mA
mV
nA
nA
V
dB
V
mA
kHz
MHz
(1) 200°c operation is a possible option. Check with the Factory.
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281
www.micropac.com E-MAIL: hybridsales@micropac.com 09/19/01