English
Language : 

42142 Datasheet, PDF (1/8 Pages) Micropac Industries – RADIATION TOLERANT POWER OPERATIONAL AMPLIFIER
ADVANCED DATA SHEET
42142
RADIATION TOLERANT
POWER OPERATIONAL AMPLIFIER
Mii
HYBRID MICROELECTRONICS
PRODUCTS DIVISION
Features:
• Design Tested to 100 krad(Si) Total Dose
• Hermetically Sealed in Metal Package
• Performance over –55°C to +125°C
• Wide Supply Voltage Range
• High Output Current
• Short Circuit Protection
Applications:
• Satellite/Space systems
• Military/High Reliability Systems
• Programmable Power Supplies
• Solenoid Driver
• Servo Motor Amplifier
• Synchro Power Amplifier
DESCRIPTION
The 42142 is a power operational amplifier designed for military and space applications where radiation tolerance is
required. Utilizing multi-chip hybrid construction, the 42142 power operational amplifier combines 10A load current
capability with the convenience of a monolithic operational amplifier. Output current limiting is provided using
external resistors. The 42142 power operational amplifier is supplied in an 8-pin hermetic flat package. This design
has demonstrated it will function with minimal degradation after exposure to 100 krad(Si) total dose. This device is
available as COTS, or screened to MIL-PRF-38534, Table C-IX, Class H or custom screening. Lead options
support both through-hole and surface-mount assembly.
ABSOLUTE MAXIMUM RATINGS:
Supply Voltage (±VS) ………………………………………………………………………………………………... ± 22 V
Input Voltage (1) ……………………………………………………………………...………………………..….……. ± 22 V
Differential Input Voltage (2) ……………………………………………….……...…………………………………. ± 0.7 V
Peak Output Current (3) …………………………………………………………………………………………………. 10 A
Storage Temperature Range …………………………………………………………………………..… -65°C to +150°C
Operating Junction Temperature ……………………………………………………………………..…. -55°C to +150°C
Lead Solder Temperature for 10 seconds ………………………………………………………….………….…….. 300°C
Power Dissipation (4) ……………..……………………………………………………………………………….……. 95 W
Linear Derating Factor …………………………………………………………………………………..………... 0.76 W/°C
WEIGHT: ………………………………………………………………….…………… ……………….. 15.2 grams (typical)
RECOMMENDED OPERATING CONDITIONS:
Parameter
Supply Voltage
Ambient Temperature
Symbol
±VS
TA
Min.
8
-55
Max.
20
125
Units
VDC
°C
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281
www.micropac.com E-MAIL: hybridsales@micropac.com 05/17/01