M3500-0408 Datasheet, PDF (1/1 Pages) Micronetics, Inc. – 400-800 MHZ TYPICAL OUTPUT FREQUENCY / MODULATION SENSITIVITY VERSUS TUNING VOLTAGE
M3500-0408 (400-800 MHZ)
1F. M3500-0408VCO TECHNICAL SPECIFICATIONS
ABSOLUTE MAXIMUM / MINIMUM RATINGS
PARAMETER
RATING
Maximum Supply Voltage
Tuning Voltage Min/Max
+15.0V
0/20V
GUARANTEED PERFORMANCE (0-70° C)
PARAMETER
DATA
Power Dissipation
Frequency Tuning Range
Power Output (50Ω)
360 mW max
(30 mA @ +12V)
400 to 800 MHz min
10 dBm min
TYPICAL PERFORMANCE (0-70° C)
PARAMETER
DATA
Nominal Supply Voltage
Power Output (50Ω)
Typical Current
Tuning Voltage
FM(Phase)Noise:
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
Frequency Pushing
Frequency Pulling (12dB Return Loss)
Harmonic Spurious (Average)
Tuning Port DC Resistance
Tuning Port Bandwidth: @ Tuning Voltage = 2.8V
@ Tuning Voltage = 9.4V
@ Tuning Voltage = 17.2V
+12V
+10 dBm
26mA
0.9 - 15.6 V
-73 dBc/Hz
<-95 dBc/Hz
<-114 dBc/Hz
<-129 dBc/Hz
1.0 MHz/V for 12 ± 1V
10 MHz peak-peak
-12 dBc
20KΩ
1.3 MHz
3.7 MHz
6.4 MHz
2F. PERFORMANCE CURVES FOR M3500-0408
400-800 MHZ TYPICAL OUTPUT FREQUENCY / MODULATION SENSITIVITY VERSUS TUNING VOLTAGE
FREQUENCY
KV ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪
400-800 MHZ VCO TYPICAL OUTPUT POWER VERSUS TUNING VOLTAGE
MICRONETICS / 26 HAMPSHIRE DRIVE / HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 / CUSTOMER HOTLINE: 1-800-963-3382 / WEB: WWW.MWIRELESS.COM