English
Language : 

HAL54X Datasheet, PDF (15/28 Pages) Micronas – Hall-Effect Sensor Family
DATA SHEET
HAL 54x
3.7. Magnetic Characteristics Overview
at TJ = −40 °C to +140 °C, VDD = 4.3 V to 24 V, Typical Characteristics for VDD = 12 V
Magnetic flux density values of switching points.
Positive flux density values refer to the magnetic south pole at the branded side of the package.
Sensor
Parameter
On point BON
Off point BOFF
Hysteresis BHYS
Unit
Switching Type TJ
HAL 542
−40 °C
Min.
1
Typ.
2.8
Max.
5
Min.
−5
Typ.
−2.8
Max.
−1
Min.
4.5
Typ.
5.85
Max.
7.2
mT
latching
25 °C 1
2.6
4.5
−4.5
−2.6
−1
4.5
5.5
6.5
mT
140 °C 0.6
2.4
4.6
−4.6
−2.4
−0.6
3.3
4.8
6.2
mT
HAL 543
−40 °C 21
27
33
15
21
27
4
6
8
mT
unipolar
25 °C 21
27
33
15
21
27
4
6
8
mT
140 °C 21
27
33
15
21
27
4
5.5
8
mT
HAL 546
−40 °C 4.3
5.9
7.7
2.1
3.8
5.5
1.5
2.1
2.9
mT
unipolar
25 °C 3.8
5.5
7.2
2
3.5
5
1.4
2
2.8
mT
140 °C 3.2
4.8
6.9
1.8
3.1
5.5
1
1.7
2.6
mT
HAL 548
−40 °C 12
19
24
6
13
18
4
6
8
mT
unipolar
25 °C 12
18
24
6
12
18
4
6
8
mT
140 °C 12
17
24
6
11
18
4
6
8
mT
Note: For detailed descriptions of the individual types, see pages 19 and following.
Micronas
Feb. 12, 2009; DSH000023_003EN
15