English
Language : 

M1500P Datasheet, PDF (6/6 Pages) GSI Group, Inc. – Mercury TM1500P PCB-Mount Digital Encoders Factory Set Resolution to 0.50μm
Standard Rotary Scales
HUB THICKNESS
SCALE
PATTERN
SCALE O.D.
MOUNTING
HOLES
Key: inches[mm]
Model No. Scale Outer
Diameter
R1206
R1910
R3213
R5725
R10851
0.472 [12.00]
0.750 [19.05]
1.250 [31.75]
2.250 [57.15]
4.250 [107.95]
HUB I.D.
OPTICAL DIAMETER
Specifications
Material
Soda lime glass
Typical CTE
8ppm/°C
Scale Inner
Diameter
0.250 [6.35]
0.375 [9.52]
0.500 [12.70]
1.000 [25.40]
2.000 [50.80]
Optical
Diameter
0.413 [10.50]
0.627 [15.92]
1.027 [26.08]
2.053 [52.15]
4.106 [104.30]
Hub Inner
Diameter
+.0005/-0.0000
0.1253 [3.18]
0.1253 [3.183]
0.2503 [6.358]
0.5003 [12.708]
1.0003 [25.408]
Custom scales available
Hub
Fundamental
Thickness
CPR
0.040 [1.02]
0.040 [1.02]
0.050 [1.27]
0.060 [1.52]
0.080 [2.03]
1650
2500
4096
8192
16384
How to Order Mercury 1500P Encoder Systems
To specify your Mercury encoder with the desired scale, consult the chart below to create the correct part number for
your order. Call MicroE Systems’ Rapid Customer Response team for more information at [781] 266-5700.
Example (linear): M1540P-L55-C1 (rotary): M1540P-R3213-HB
M15xxP – Scale Model – Scale Mounting
M1504P = 4x interpolation
M1508P = 8x
M1520P = 20x
M1540P = 40x
Lxxx or Rxxxx
For Linear Scales:
T = Tape Mounting
C1 = 3 scale clamps*
C2 = 10 scale clamps**
Hubs for Rotary Scales:
NH = No hub
HE = for R1206
HA = for R1910
HB = for R3213
HC = for R5725
HD = for R10851
* 3 clamps come standard with linear scales up to 130mm
** 10 clamps come standard with linear scales 155mm or longer
All Specifications are subject to change. All data is accurate to the best of our knowledge.
MicroE Systems is not responsible for errors.
MicroE Systems – World Headquarters: 125 Middlesex Turnpike • Bedford • MA 01730
DS-M1500P Rev 1 © 2008 MicroE Systems www.microesys.com • info@microesys.com • T. [781]-266-5700 • F. [781]-266-5112
Page 6 of 6