Minimum load
B-XM-2WSeries
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading
will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2s and output capacitance of 10F, are shown in the table below. The product
series will start into a capacitance of 47F with an increased start time, however, the maximum recommended output capacitance is 10F.
Start-up time
B0505XM
B0509XM
B0512XM
B0515XM
B1205XM
B1209XM
B1212XM
B1215XM
790
1154
2265
2998
396
880
1156
2394
General Characteristics
Parameter
Switching frequency
Temperature Characteristics
Parameter
Specification
Storage
Case temperature above
ambient
Cooling
Temperature derating graph
Conditions
5V input types
12V input types
Conditions
All output types
5V output types
All other output types
Free air convection
Min.
Typ.
90
90
Max.
Units
kHz
kHz
Min.
-40
-50
Typ.
Max.
85
130
45
36
Units
℃
Tolerance envelope
The voltage tolerance envelope shows typical load regulation characteristics for this
product series. The tolerance envelope is the maximum output voltage variation due
to changes in output loading.