OUTPUT CHARACTERISTICS
Parameter
Rated Power1
Voltage Set Point Accuracy
Line regulation
Load regulation
10% to 100% load
Conditions
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
3.3V output
5V output
9V output
12V output
15V output
24V output
B-X(S)D-2WSeries
Min.
0.2
Typ.
1.05
12
12.8
8.3
6.8
6.3
6.0
Max.
2
1.2
20
15
15
15
15
15
Units
W
%%
%
%
%
%
%
%
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2s and output capacitance of 10F, are swn in the table below. The product
series will start into a capacitance of 47F with an increased start time, however, the maximum recommended output capacitanceis 10F
Typical Start-Up Wave Form
Start-up time
B0505XS
B0509XS
B0512XS
B0515XS
B1205XS
B1209XS
B1212XS
B1215XS
444
1120
1930
3470
409
1320
1320
2270
Isolation Characteristics
Parameter
Isolation voltage
Resistance
General Characteristics
Parameter
Switching frequency
Temperature Characteristics
Parameter
Specification
Storage
Case temperature above
ambient
Conditions
Flash tested for 1 second
Viso= 500VDC
Conditions
Conditions
All output types
B0505S output types
B1205S output types
All other output types
Min.
1000
1000
Typ.
Max.
Units
VDC
MΩ
Min.
Typ.
60
Max.
Units
kHz
Min.
-40
-50
Typ.
Max.
85
125
30
25
20
Units
℃
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 2 of 5