English
Language : 

WRN78-500 Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – WIDEINPUT,NON-ISOLATED REGULATEDSINGLEOUTPUTSIP3DC/DCCONVERTER
WRN78XX-500 Series
WIDE INPUT,NON-ISOLATED REGULATED SINGLE OUTPUT SIP3 DC/DC CONVERTER
FEATURES
◆RoHS compliant
◆Efficiency up to 96%
◆SIP Package
◆Wide temperature range:-40°C to 85°C
◆Short circuit protection,Thermal Shutdown
◆No heatsink required
◆ Low ripple and noise
◆ Industry standard pinout
◆MTBF>2,000,000 hours
◆Only two extra capacitors are required
◆ Input voltage range can be lower than the
output voltage for higher output voltages
◆ The WRN78xx-500 Series converters
can also be used to convert a positive
voltage into a negative voltage
MODEL SELECTION
WRN78①05②-500③
①Product Series
③Output Current
②Output Voltage
DESCRIPTION
The WRN78xx-500 Series high efficiency switching
Regulators are ideally suited to replace 78xx linear
regulators and are pin compatible.
MICRODC reserves the copyright
SELECTION GUIDE
order code
WRN7803-500
Input
Voltage Range
(VDC)
4.75-28
4.75-25
Output
Voltage
(VDC)
3.3
Current
(MA)
500
-3.3
-400
Efficiency(%,Typ)
Vin(min)
90
73
Vin(max)
80
78
6.5-32
5.0
500
93
84
WRN7805-500
6.0-27
-5.0
-400
78
83
WRN786.5-500
8-32
6.5
500
94
87
6.0-25
-6.5
-300
83
85
11-32
9.0
500
95
91
WRN7809-500
7.0-23
-9.0
-200
87
86
15-32
12
500
95
92
WRN7812-500
7.0-20
-12
-200
85
87
WRN7815-500
18-32
15
500
96
93
7.0-17
-15
-200
84
89
*Input voltage can't exceed this value,or will cause the permanent damage.
OUTPUT SPECIFICATIONS
Parameter
Test conditions
Output Voltage accuracy
100% full load
Line regulation
Vin= min. to max. at full load
Load regulation
10% to 100% load
Ripple&Noise*
20MHZ Bandwidth
Short Circuit Input Power
Short circuit protection
Switching frequency
Quiescent current
Positive Output
Quiescent current
Negative Output
Thermal Shutdown
Internal IC junction
Temperature coefficient
-40 °C to +85 °C ambient
Max capacitance load
* Test ripple and noise by "parallel cable" method.
Min.
Typ.
Max.
Units
±2
±3
W
±0.2
±0.4
%
±0.4 ±0.6
%
20
35
%
0.5
1.8
%
Continuous, automatic recovery
280
330
450
Khz
5
8
mA
7
13
150
℃
0.02
%/℃
1000
µF
COMMON SPECIFICATIONS
Parameter
Operating Temp. Range
Operating Case Temp.
Storage Temp. Range
Cooling
Case Material
Lead Temperature
Storage Humidity Range
MTBF
Package Weight
Note:
Test conditions
1.5mm from case for 10 seconds
+25°C MIL-HDBK-217F
Min.
-40
-55
2000
Typ.
Max. Units
85
℃
100
℃
125
℃
Free Air Convection
Plastic (UL94-V0)
300
℃
95
%
K hours
2.0
g
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output
load unless otherwise specified.
2. Only typical models listed. If you need other model, please confirm the power, input voltage and output voltage,
then phone us.
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 2