English
Language : 

WRA1205YQD-40W Datasheet, PDF (1/3 Pages) Microdc power Technology Co., Ltd – 30W~40W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
WRA-YQD-40&WRB-YQD-40W
30W~40W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
FEATURES
◆Wide 2:1 DC input range
◆In/out capacitance1000pF
◆Protections : Short circuit / Overload / Over voltage
◆1500VDC I/O isolation for D/D
◆Cooling by free air convection
◆Built-in remote ON-OFF control
◆100% full load burn-in test
◆Fixed switching frequency at 225KHz
◆Lost cost
◆MTBF>1000Khours
◆High reliability and compatibility
◆3 year warranty
MODEL SELECTION
WRB①24②12③Y④QD⑤-40W(3334)⑥
①Product Series ②Input Voltage
③Output Voltage ④Wide (2:1) Input Range
⑤2"×2"DIP Package Style
⑥Rated Power(Output current)
APPLICATIONS
The WRA(B)-YQD-40W Series of DC/DC
converters has been designed for a wide range of
applications including communications, industrial
systems and battery powered mobile equipments.
Key features are high power density and 2:1 wide
input ranges of 18~36 VDC and 36~72 VDC.(But
also can do high power density and 4:1 ultrawide
input ranges of 9~36 VDC and 18~72 VDC.)
MICRODC R ESERVES THE COPYRIGHT
SELECTION GUIDE
Order code
Input voltage range
(VDC)
WRA1205YQD-40W
WRA1212YQD-40W
WRA1215YQD-40W
WRA1224YQD-40W
WRA2405YQD-40W
WRA2412YQD-36W
WRA2412YQD-40W
WRA2415YQD-40W
WRA2424YQD-40W
WRA4805YQD-40W
WRA4812YQD-40W
WRA4815YQD-40W
WRA4824YQD-40W
WRB1205YQD-40W
WRB1212YQD-40W
WRB1215YQD-40W
WRB1224YQD-40W
WRB2405YQD-40W
WRB2412YQD-36W
WRB2412YQD-40W
WRB2415YQD-40W
WRB2424YQD-40W
WRB4805YQD-40W
WRB4812YQD-40W
WRB4815YQD-40W
WRB4824YQD-40W
9~18
9~18
9~18
9~18
18~36
18~36
18~36
18~36
18~36
36~72
36~72
36~72
36~72
9~18
9~18
9~18
9~18
18~36
18~36
18~36
18~36
18~36
36~72
36~72
36~72
36~72
Output voltage
(VDC)
±5
±12
±15
±24
±5
±12
±12
±15
±24
±5
±12
±15
±24
5
12
15
24
5
12
12
15
24
5
12
15
24
Output current
max.(mA)
±4000
±1667
±1334
±834
±4000
±1500
±1667
±1334
±834
±4000
±1667
±1334
±834
8000
3334
2666
1667
8000
3000
3334
2666
1667
8000
3334
2666
1667
Efficiency typ.(%)
78
82
80
83
79
86
82
83
78
80
84
85
78
79
80
80
85
82
87
82
83
78
80
84
85
79
SPECIFICATION
OUTPUT
PROTECTION
FUNCTION
Ripple&Noise(max.)
Line Regulation
Load Regulation
Overload
Over Voltage
Short Circuit
ON/OFF Control
(Note.2)
100mVp-p
(Note.3)
±0.5%
(Note.4)
±0.5%
Above 105% rated output power
Protection type : Over power limiting, recovers automatically after fault
condition is removed
XX03 :3.8~4.95V
XX05 :5.75 ~ 7.5V
XX12:13.8 ~ 18V
XX15:17.25 ~ 22.5V
Protection type : Shut off o/p voltage, clamping by zener diode
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
Power on: CTRL ~-Vin > 4.5~5.5VDC or open
Power off : CTRL~ -Vin <0.8VDC or short
ENVIRONMENT
SAFETY&EMC
(Note 5)
OTHERS
NOTE
Working Temp.
Storage Temp.,Humidity
Temp. Coefficient
Safety Standards
Isolation Voltage
Isolation Resistance
-25℃~+85℃ (Refer to output load derating curve)
-25℃~+85℃, 0~95% RH
±0.03%/ ℃(0~50℃)
Design refer to LVD
I/P-O/P:1.5KVDC
I/P-O/P:100M Ohms/500VDC
MTBF
280.4K hrs min.
MIL-HDBK-217F (25℃)
Dimension
50.8×50.8×16mm (2"×2"×0.63") (L×W×H)
Packing
110g;150pcs/15.8Kg/0.97CUFT
1. All parameters are specified at normal input, rated load, 2570% RH ambient.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100%rated load
5. Please prevent the converter from operating in overload or short circuit condition for
more than 30 seconds.