RB-XS Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – 0.5 Watt SIP4 Single Output DC/DC-Converter | |||
|
FEATURES
âIndustry Standard Pin out
â1kVDC Isolation
âUL94V-0 Package Material
âOptional Continuous Short Circuit Protected
âFully Encapsulated
âCustom Solutions Available
âEfficiency to 87%
â3 year Warranty
MODEL SELECTION
RBâ 05â¡05â¢X⣠Sâ¤
â Product Series
â¢Output Voltage
â¤SIP Package
â¡Input Voltage
â£Fixed Input
APPLICATIONS
The RB-XS DC/DC converters are typically
used in general purpose low power isolation
and voltage matching applications, and feature
a full industrial operating temperature range of
-40â~ +85â without derating.
Derating-Graph(Ambient Temperature)
MICRODC R ESERVES THE COPYRIGHT
RB-XS Series
0.5 Watt SIP4 Single Output DC/DC-Converter
SELECTION GUIDE
Model
RB0505XS
Input
Voltage
(V)
5
Output
Voltage
(V)
5
Output Current
(MA)
100
Efficiency
(%)
80
RB1205XS
12
5
100
82
RB0512XS
5
12
42
83
RB1212XS
12
12
42
86
RB0515XS
5
15
33
84
RB1215XS
12
15
33
87
add âPâ for Continuous Short Circuit Protection,e.g.:RB0505XSP
Max.
Capacitive
Load
470μF
470μF
150μF
150μF
150μF
150μF
Specifications
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ..
Load Voltage Regulation (10% to 100% full load)
10% max. / 4% typ..
Output Ripple and Noise (20MHz limited)
100mVp-p max.
Operating Frequency
20kHz min. / 54kHz typ.
Efficiency at Full Load
Efficiency at 50%l Load
70% min. / 85% typ.
65% min. / 80% typ.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Isolation Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute)
500VAC / 60Hz
Isolation Capacitance
20pF min. / 75pF max.
Isolation Resistance
10 Gâ¦min.
Short Circuit Protection
Suffix "P"
1 Second
Continuous
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graphï¼
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
1.4g
Packing Quantity
42 pcs per Tube
MTBF (+25°C)
(+85°C)
} Detailed Information see
Application Notes chapter
"MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
985 x 103hours
200 x 103hours
(measured at TA= 25â, nominal input voltage, full load and after warm-up )
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 2
|
▷ |