English
Language : 

IE-XS-1W Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – FIXED INPUT,ISOLATED & REGULATED Dual Output DC/DC Converter
IE-XS-1W Series
FIXED INPUT,ISOLATED & REGULATED Dual Output DC/DC Converter
FEATURES
◆RoHS compliant
◆Efficiency up to 86%
◆SIP Package
◆Wide temperature performance at full
1 Watt load,-40°C to 85°C
◆UL 94V-0 package material
◆No heatsink required
◆Low ripple and good EMC Features
◆Industry standard pinout
◆Power sharing on output
◆3KVDC isolation
◆Continuous Short Circuit Protection
◆Internal SMD construction
◆No external components required
◆Good dynamic feature
MODEL SELECTION
IE①05②05③X④ S⑤-1W⑥
①Product Series
③Output Voltage
⑤SIP Package
②Input Voltage
④Fixed Input
⑥Rated Power
SELECTION GUIDE
Order code
Input
Voltage(VDC)
Nominal
Range
IE0505XS-1W
5
4.75-5.25
IE0509XS-1W
5
4.75-5.25
IE0512XS-1W
5
4.75-5.25
IE0515XS-1W
5
4.75-5.25
IE1205XS-1W
12
11.4-12.6
IE1209XS-1W
12
11.4-12.6
IE1212XS-1W
12
11.4-12.6
IE1215XS-1W
12
11.4-12.6
IE2405XS-1W
24
22.8-25.2
IE2409XS-1W
24
22.8-25.2
IE2412XS-1W
24
22.8-25.2
IE2415XS-1W
24
22.8-25.2
Voltage
(VDC)
±5
±9
±12
±15
±5
±9
±12
±15
±5
±9
±12
±15
Output
Current(MA)
Max
Min
±100
±10
±56
±6
±42
±5
±33
±4
±100
±10
±56
±6
±42
±5
±33
±4
±100
±10
±56
±6
±42
±5
±33
±4
Efficiency
(%,Typ)
69
61
62
64
72
61
63
64
72
60
63
64
Switching
Frequency
(KHz,Typ)
83
83
83
250
100
83
83
83
83
83
83
300
ISOLATION SPECIFICATIONS
Parameter
Isolation test voltage
Isolation resistance
Test conditions
Flash tested for 1 minute and 1mA max
Test at Viso=500VDC
Min.
3000
1000
Typ.
Max.
Units
VDC
MΩ
APPLICATIONS
The IE_XS-1W series are specially designed for applications
where a group of polar power supplies are isolated from the
input power supply in a distributed power supply system on a
circuit board.
These products apply to:
1) where the voltage of the input power supply is fixed
(voltage variation ≤±5%);
2) where isolation is necessary between input and output
(isolation voltage ≤3000VDC);
3) where the regulation of the output voltage and the output
ripple noise are demanded.
MICRODC reserves the copyright
OUTPUT SPECIFICATIONS
Parameter
Output power
Line regulation
Load regulation
Output voltage accuracy
Temperature drift
Output Ripple*
Output Noise*
Switching frequency
Test conditions
For Vin change of ±5%
10% to 100% full load
100% full load
100% full load
20MHz Bandwidth
20MHz Bandwidth
Full load,nominal input
Min Typ.
0.1
10
50
100
Max.
1
±0.25
±1
±3
0.03
20
100
Units
W
%
%
%
%/°C
MV p-p
MV p-p
Khz
* Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 2