English
Language : 

IB0505XS-2W Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – FIXED INPUT,ISOLATED®ULATED Single Output DC/DC Converter
IB-XS-2W Series
FIXED INPUT,ISOLATED&REGULATED Single Output DC/DC Converter
FEATURES
◆RoHS compliant
◆Efficiency up to 84%
◆SIP7 Package
◆Wide temperature performance at full
2 Watt load,-40℃~85℃
◆UL 94V-0 package material
◆No heat sink required
◆Small Footprint
◆Industry standard pin out
◆Power sharing on output
◆1KVDC isolation
◆Continuous Short Circuit Protection
◆Internal SMD construction
◆No external components required
◆MTTF up to 1.5 million hours
MODEL SELECTION
IB①05②05③X④ S⑤-2W⑥
①Product Series
③Output Voltage
⑤SIP7 Package
②Input Voltage
④Fixed Input
⑥Rated Power
APPLICATIONS
The IB_XS-2W series are specially designed
for applications where a group of polar power
supplies are isolated from the input power
supply in a distributed power supply system on
a circuit board.
These products apply to:
1) where the voltage of the input power supply
is fixed (voltage variation ≤±5%);
2) where isolation is necessary between input
and output (isolation voltage ≤1000VDC);
3) where the regulation of the output voltage
and the output ripple noise are demanded.
SELECTION GUIDE
Order code
Input
Voltage(VDC)
Nominal
Range
IB0505XS-2W
5
4.75-5.25
IB0512XS-2W
5
4.75-5.25
IB0515XS-1W5
5
4.75-5.25
IB1205XS-2W
12
11.4-12.6
IB1215XS-1W5
12
11.4-12.6
IB1215XS-2W
12
11.4-12.6
IB1505XS-2W
15
14.25-15.
IB2405XS-2W
24
22.8-25.2
IB2415XS-2W
24
22.8-25.2
Voltage
(VDC)
5
12
15
5
15
15
5
5
15
Output
Current(MA)
Max
Min
400
40
167
17
100
10
400
40
100
10
133
13
400
40
400
40
133
13
Efficiency
(%,Typ)
70
78
75
71
76
76
71
71
75
Switching
Frequency
(KHz,Typ)
100
96
97
55
90
87
67
67
65
ISOLATION SPECIFICATIONS
Parameter
Isolation test voltage
Isolation resistance
Test conditions
Flash tested for 1 minute and 1mA max
Test at Viso=500VDC
Min.
1000
1000
Typ. Max.
Units
VDC
MΩ
OUTPUT SPECIFICATIONS
Parameter
Output power
Line regulation
Load regulation
Output voltage accuracy
Temperature drift
Output Ripple*
Output Noise*
Switching frequency
Test conditions
For Vin change of ±5%
10% to 100% full load
100% full load
100% full load
20MHz Bandwidth
20MHz Bandwidth
Full load,nominal input
Min Typ.
0.2
20
50
100
Max.
2
±0.25
±1.5
±3
0.03
30
100
Units
W
%
%
%
%/°C
MV p-p
MV p-p
Khz
* Test ripple and noise by "parallel cable" method.
See detailed operation instructions at Testing of Power Converter section, application notes.
MICRODC R ESERVES THE COPYRIGHT
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 2