H-XVD Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – 1W,FIXED INPUT,6000V ISOLATED&UNREGULATED SINGLE/DUAL OUTPUT DC-DC CONVERTER | |||
|
H-XVD&G-XVD Series
1W,FIXED INPUT,6000V ISOLATED&UNREGULATED SINGLE/DUAL OUTPUT DC-DC CONVERTER
FEATURES
âSmall Footprint
âDIP24 Package
â6KVDC Isolation
âTemperature Range: -40âï½+85â
âNo Heat Sink Require
âNo External Component Require
âInternal SMD Construction
âIndustry Standard Pin out
âRoHS Compliance
PRODUCT PROGRAM
Order code
Input
Voltage(VDC)
Nominal
Range
H0505XVD
H0509XVD
H0512XVD
H0515XVD
G0505XVD
5
4.5-5.5
G0509XVD
G0512XVD
G0515XVD
H1205XVD
H1209XVD
H1212XVD
H1215XVD
G1205XVD
12
10.8-13.2
G1209XVD
G1212XVD
G1215XVD
Voltage
(VDC)
5
9
12
15
±5
±9
±12
±15
5
9
12
15
±5
±9
±12
±15
Output
Current
Max
Min
200
20
111
12
84
9
67
7
±100
±10
±56
±6
±42
±5
±33
±4
200
20
111
12
84
9
67
7
±100
±10
±56
±6
±42
±5
±33
±4
Efficiency
(%,Typ)
70
72
73
74
70
71
72
73
70
71
72
74
70
71
72
75
Switching
Frequency
(KHz,Typ)
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
MODEL SELECTION
Hâ 05â¡05â¢X⣠Vâ¤Dâ¥
â Product Series
â¡Input Voltage
â¢Output Voltage
â£Fixed Input
â¤Footprint Rank Shape â¥DIP24 Package
ISOLATION SPECIFICATIONS
Item
Isolation voltage
Isolation resistance
Isolation capacitance
Test Conditions
Tested for 1 minute and 1mA max
Test at 1000VDC
Min
Typ Max Units
6000
VDC
1000
MΩ
3.5
pF
APPLICATIONS
The G-XVD& H-XVD Series are
specially designed for applications where a
group of polar power supplies are isolated
from the input power supply in a distributed
power supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power
supply is fixed (voltage variation â¤10%);
2) Where isolation is necessary between
input and output (isolation voltage
â¤6000VDC);
3) Where the regulation of the output
voltage and the output ripple noise are not
demanded.
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
MICRODC R ESERVES THE COPYRIGHT
COMMON SPECIFICATIONS
Item
Storage humidity range
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
Short circuit protection*
Cooling
Case material
MTBF
Weight
Test Conditions
1.5mm from case for 10 seconds
5V input voltage
12V input voltage
Min
Typ Max Units
95
%
-40
85
-55
125
â
15
30
300
1
S
Continuous
Free air convection
Plastic(UL94-V0)
3500
8.2
K hours
g
* When input voltage (Nominal) is 5V, Supply voltage must be discontinued at the end of short circuit
duration.
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 2
|
▷ |