English
Language : 

F-XMS Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – 1W, FIXED INPUT, ISOLATED&UNREGULATED SINGLE OUTPUT DC-DC CONVERTER
F-XMS Series
1W, FIXED INPUT, ISOLATED&UNREGULATED SINGLE OUTPUT DC-DC CONVERTER
FEATURES
◆ High Efficiency up to 79%
◆ 3000VDC Isolation
◆ Temperature Range: -40℃~+85℃
◆ No Heat sink Required
◆ No External Component Required
PRODUCT PROGRAM
Part
Number
Input
Voltage (VDC)
Nominal Range
F0303XMS
F0305XMS
F0309XMS
F0503XMS
F0505XMS
F0509XMS
F0512XMS
F0515XMS
F1203XMS
F1205XMS
F1209XMS
F1212XMS
F1215XMS
3.3
3.0-3.6
3.3
3.0-3.6
3.3
3.0-3.6
5
4.5-5.5
5
4.5-5.5
5
4.5-5.5
5
4.5-5.5
5
4.5-5.5
12
10.8-13.2
12
10.8-13.2
12
10.8-13.2
12
10.8-13.2
12
10.8-13.2
Voltage
(VDC)
3.3
5
9
3.3
5
9
12
15
3.3
5
9
12
15
Output
Current (mA)
Min
Max
300
30
200
20
111
12
300
30
200
20
111
12
83
9
67
7
300
30
200
20
111
12
83
9
67
7
Efficiency
(%,Typ)
Package
Style
70
SIP4
73
SIP4
74
SIP4
71
SIP4
69
SIP4
76
SIP4
78
SIP4
78
SIP4
74
SIP4
71
SIP4
74
SIP4
78
SIP4
79
SIP4
◆ No External Component Required
◆ Industry Standard Pin out
◆ RoHS Compliance
MODEL SELECTION
F①05②05③X④MS⑤
①Product Series
②Input Voltage
③Output Voltage
④Fixed Input
⑤Mini SIP4 Package
DESCRIPTION
The F-XMS Series is specially designed for
applications where a group of polar power
supplies are isolated from the input power
supply in a distributed power supply system on
a circuit board.
These products apply to:
1) Where the voltage of the input power
supply is fixed (voltage variation ≤10%);
2) Where isolation is necessary between
input and output (isolation voltage ≤3000VDC);
3) Where the regulation of the output voltage
and the output ripple noise are not demanding.
Such as:purely digital circuits,ordinary low
frequency analog circuits,and IGBT power
device driving circuits.
MICRODC R ESERVES THE COPYRIGHT
ISOLATION SPECIFICATIONS
Item
Isolation voltage
Isolation resistance
Isolation Capacitance
Test conditions
Tested for 1 minute and 1 mA max
Test at 500VDC
Min Typ Max Units
3000
VDC
1000
MΩ
60
pF
COMMON SPECIFICATIONS
Item
Test conditions
Min Typ Max Units
Storage humidity
95
%
Operating Temperature
Storage Temperature
Temp. rise at full load
Lead temperature
1.5mm from case for 10 seconds
-40
85
-55
125
℃
15
30
300
Short circuit protection*
1
S
Cooling
Case material
MTBF
Free air convection
Plastic (UL94-V0)
3500
K hours
Weight
4.3
g
*Supply voltage must be discontinued at the end of short circuit duration.
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 2