English
Language : 

B-XS-W5 Datasheet, PDF (1/2 Pages) Microdc power Technology Co., Ltd – 0.5Watt SIP4 SingleOutputDC/DC-Converter
B-XS-W5 Series
0.5 Watt SIP4 Single Output DC/DC-Converter
FEATURES
◆Industry Standard Pinout
◆1kVDC Isolation
◆UL94V-0 Package Material
◆Optional Continuous Short Circuit Protected
◆Fully Encapsulated
◆Custom Solutions Available
◆Efficiency to 87%
◆3 year Warranty
MODEL SELECTION
B①05②05③X④ S⑤-W5⑥
①Product Series
③Output Voltage
⑤SIP Package
②Input Voltage
④Fixed Input
⑥Rated Power
APPLICATIONS
The B-XS-W5 DC/DC converters are typically
used in general purpose low power isolation
and voltage matching applications, and feature
a full industrial operating temperature range of
-40℃~ +85℃ without derating.
Derating-Graph(Ambient Temperature)
SELECTION GUIDE
Model
B0505XS-W5
Input
Voltage
(V)
5
B1205XS-W5
12
B0512XS-W5
5
B1212XS-W5
12
B0515XS-W5
5
B1215XS-W5
12
Output
Voltage
(V)
5
5
12
12
15
15
Output Current
(MA)
100
100
42
42
33
33
Efficiency
(%)
80
82
83
86
84
87
Max.
Capacitive
Load
470μF
470μF
150μF
150μF
150μF
150μF
Specifications
Input Voltage Range
±10%
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ..
Load Voltage Regulation (10% to 100% full load)
10% max. / 4% typ..
Output Ripple and Noise (20MHz limited)
100mVp-p max.
Operating Frequency
20kHz min. / 54kHz typ.
Efficiency at Full Load
70% min. / 85% typ.
Efficiency at 50%l Load
65% min. / 80% typ.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Isolation Voltage
(tested for 1 second)
1000VDC
(rated for 1 minute)
500VAC / 60Hz
Isolation Capacitance
20pF min. / 75pF max.
Isolation Resistance
10 GΩmin.
Short Circuit Protection
1 Second
Suffix "P"
Continuous
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
1.4g
Packing Quantity
42 pcs per Tube
MTBF (+25°C)
(+85°C)
} Detailed Information see
Application Notes chapter
"MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
985 x 103hours
200 x 103hours
(measured at TA= 25℃, nominal input voltage, full load and after warm-up )
add “P” for Continuous Short Circuit Protection,e.g.:B0505XS-W5P
MICRODC reserves the copyright
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 2