MCP4726A2T-E Datasheet, PDF (48/86 Pages) Microchip Technology – 8-/10-/12-Bit Voltage Output Digital-to-Analog Converter | |||
|
◁ |
MCP4706/4716/4726
5.3.7 GENERAL CALL
The General Call is a method that the âmasterâ device
can communicate with all other âslaveâ devices. In a
multi-master application, the other master devices are
operating in Slave mode. The General Call address
has two documented formats. These are shown in
Figure 5-11.
The MCP47X6 has two General Call commands. The
function of these commands are:
⢠Reset the device(s) (Software Reset)
⢠Wake-Up the device(s)
For details on the operation of the MCP47X6âs General
Call commands, see Section 6.6 âI2C General Call
Commandsâ.
Note:
Only one General Call command per issue
of the General Call control byte. Any
additional General Call commands are
ignored and Not Acknowledged.
Second Byte
S0000 0000 A x xxx Xx x0AP
General Call Address
â7-bit Commandâ
Reserved 7-bit Commands (By I2C Specification â NXP specification # UM10204, Rev. 03 19 June 2007)
â0000 011âb - Reset and write programmable part of slave address by hardware
â0000 010âb - Write programmable part of slave address by hardware
â0000 000âb - NOT Allowed
The Following is a âHardware General Callâ Format
Second Byte
n occurrences of (Data + A)
S 0 0 0 0 0 0 00 A x x x x X x x 1 A x x x x X x x X A P
General Call Address
âMaster Addressâ
FIGURE 5-11:
General Call Formats.
This indicates a âHardware General Callâ
DS22272C-page 48