HCS500-I Datasheet, PDF (24/34 Pages) Microchip Technology – KEELOQ Code Hopping Decoder | |||
|
◁ |
HCS500
8.1.7 ERASE ALL COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ⤠TA ⤠+70°C
Industrial (I):
-40°C ⤠TA ⤠+85°C
Symbol
Parameters
Min
Typ
Max
Units
TERA Learn command activation time
20
TACK Decoder acknowledge time
20
TRESP
Microcontroller acknowledge
response time
20
TACK2 Decoder data line low
â
* These parameters are characterized but not tested.
â
1000
µs
â
210
ms
â
1000
µs
â
10
µs
8.1.8 PROGRAMMING COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ⤠TA ⤠+70°C
Industrial (I):
-40°C ⤠TA ⤠+85°C
Symbol
Parameters
Min
Typ
Max
Units
TPP1 Command request time
â
TPP2 Decoder acknowledge time
â
TPP3
Start Command mode to first
command bit
20
TPP4 Data line low before tri-stated
â
TCLKH Clock high time
20
TCLKL Clock low time
20
FCLK Clock frequency
500
TDS Data hold time
â
TCMD Command validate time
â
TACK Command acknowledge time
30
TWT2 Acknowledge respond time
20
TALW Data low after clock low
â
* These parameters are characterized but not tested.
â
500
ms
â
1
ms
â
1000
µs
â
5
µs
â
1000
µs
â
1000
µs
â
25000
Hz
â
5
µs
â
10
µs
â
240
ms
â
1000
µs
â
10
µs
DS40153C-page 24