|
MCP9808-E-MS Datasheet, PDF (19/52 Pages) Microchip Technology – 0.5°C Maximum Accuracy Digital Temperature Sensor | |||
|
◁ |
MCP9808
REGISTER 5-2: CONFIG: CONFIGURATION REGISTER (â ADDRESS â0000 0001âb)
bit 7
Crit. Lock: TCRIT Lock bit
0 = Unlocked. TCRIT register can be written (power-up default)
1 = Locked. TCRIT register can not be written
When enabled, this bit remains set to â1â or locked until cleared by an internal Reset (Section 5.3
âSummary of Power-on Defaultâ).
This bit can be programmed in Shutdown mode.
bit 6
Win. Lock: TUPPER and TLOWER Window Lock bit
0 = Unlocked; TUPPER and TLOWER registers can be written (power-up default)
1 = Locked; TUPPER and TLOWER registers can not be written
When enabled, this bit remains set to â1â or locked until cleared by a Power-on Reset (Section 5.3
âSummary of Power-on Defaultâ).
This bit can be programmed in Shutdown mode.
bit 5
Int. Clear: Interrupt Clear bit
0 = No effect (power-up default)
1 = Clear interrupt output; when read, this bit returns to â0â
This bit can not be set to â1â in Shutdown mode, but it can be cleared after the device enters Shutdown
mode.
bit 4
Alert Stat.: Alert Output Status bit
0 = Alert output is not asserted by the device (power-up default)
1 = Alert output is asserted as a comparator/Interrupt or critical temperature output
This bit can not be set to â1â or cleared to â0â in Shutdown mode. However, if the Alert output is config-
ured as Interrupt mode, and if the host controller clears to â0â, the interrupt, using bit 5 while the device
is in Shutdown mode, then this bit will also be cleared â0â.
bit 3
Alert Cnt.: Alert Output Control bit
0 = Disabled (power-up default)
1 = Enabled
This bit can not be altered when either of the Lock bits are set (bit 6 and bit 7).
This bit can be programmed in Shutdown mode, but the Alert output will not assert or deassert.
bit 2
Alert Sel.: Alert Output Select bit
0 = Alert output for TUPPER, TLOWER and TCRIT (power-up default)
1 = TA > TCRIT only (TUPPER and TLOWER temperature boundaries are disabled)
When the Alarm Window Lock bit is set, this bit cannot be altered until unlocked (bit 6).
This bit can be programmed in Shutdown mode, but the Alert output will not assert or deassert.
bit 1
Alert Pol.: Alert Output Polarity bit
0 = Active-low (power-up default; pull-up resistor required)
1 = Active-high
This bit cannot be altered when either of the Lock bits are set (bit 6 and bit 7).
This bit can be programmed in Shutdown mode, but the Alert output will not assert or deassert.
bit 0
Alert Mod.: Alert Output Mode bit
0 = Comparator output (power-up default)
1 = Interrupt output
This bit cannot be altered when either of the Lock bits are set (bit 6 and bit 7).
This bit can be programmed in Shutdown mode, but the Alert output will not assert or deassert.
© 2011 Microchip Technology Inc.
DS25095A-page 19
|
▷ |