English
Language : 

SST49LF160C Datasheet, PDF (15/37 Pages) Silicon Storage Technology, Inc – 16 Mbit LPC Flash
16 Mbit LPC Flash
SST49LF160C
Device Commands
EOL Data Sheet
Device operation is controlled by commands written to the Command User Interface (CUI). Execution
of a specific command is handled by internal functions after a CUI receives and processes the com-
mand. After power-up or a Reset operation the device enters Read mode. Commands consist of one
or two sequential Bus-Write operations. The commands are summarized in Table 8, “Software Com-
mand Sequence”.
Table 8: Software Command Sequence
Command
Bus Cycles
Required
First Bus Cycle
Oper Addr1 Data
Second Bus Cycle
Oper Addr1 Data
Read-Array/Reset
Read-Software-ID2/
Read-Security-ID3
Read-Status-Register3
1
Write
X
FFH
2
Write
X
90H Read
IA4
ID5
2
Write
X
70H Read
X
SRD6
Clear-Status-Register
Sector-Erase7
Block-Erase7
Program7,9
1
Write
X
50H
2
Write
X
30H Write SAx8 D0H
2
Write
X
20H Write BAx D0H
2
Write
X
40H
Write WA10 WD11
or
10H
Program-/Erase-Suspend
1
Write
X
B0H
Program-/Erase-Resume
User-Security-ID-Program12
1
Write
X
D0H
2
Write
X
A5H Write WA10 Data
User-Security-ID-Program-Lockout
2
Write
X
85H Write
X
00H
T8.0 25099
1. This value must be a valid address within the device Memory Address Space. X can be VIH or VIL, but no other value.
2. SST Manufacturer’s ID = BFH, is read with A20-A0 = 0.
SST49LF160C Device ID = 4CH, is read with A20-A1 = 0, A0 = 1.
Following the Read-Software-ID/Read-Security-ID command,
Read operations access Manufacturer’s ID and Device ID or Security ID.
3. Following the Read-Software-ID/Read-Security-ID command, Read operations access manufacturer’s ID and Device ID
or Security ID. Read-Software-ID/Read-Security-ID and Read-Status-Register will return register data until another
valid command is written.
4. IA = Device Identification Address/Security ID Address.
5. ID = Data read from identifier codes/Data read from Security ID
6. SRD = Data read from Status register
7. The sector or block must not be write-locked when attempting Erase or Program operations.
Attempts to issue an Erase or Program command to a write-locked sector/block will fail.
8. SAX for Sector-Erase Address
BAX for Block-Erase Address
9. The Program command operates on one byte at a time.
10. WA = Address of memory location to be written
11. WD = Data to be written at location WA
12. Valid addresses for the User Security ID space are from FFFC 0188H to FFFC 019FH.
© 2016
DS20005099B
02/16
15