To use the strapping option, set the Config. Select switch to "Strap", position 2-3. The
green LED will light. Select the desired CFG_BC and CFG_Non-Rem options by
enabling only one position for each of the Config_Bat_Chrg Select and Con-
fig_Non_Rem Select switches (SW5 and SW6).
FIGURE 2-3:
STRAPPING OPTIONS
TABLE 2-1: STRAPPING OPTIONS FOR BATTERY CHARGING
SW5 Position
Configuration
1
No BC Enabled
2
Port 1 is BC Enabled
3
Port 1 & 2 are BC Enabled
4
Port 1, 2 & 3 are BC Enabled
5
Port 1, 2, 3 & 4 are BC Enabled [default]
6
Reserved
TABLE 2-2: STRAPPING OPTIONS FOR PORT REMOVABLE
SW6 Position
Configuration
1
All ports are Removable [default]
2
Port 1 is Non-Removable
3
Port 1 & 2 are Non-Removable
4
Port 1, 2 & 3 are Non-Removable
5
Port 1, 2, 3 & 4 are Non-Removable
6
Reserved
2.1.5 Port Power Options: Port Enable and Port Disable Select
Any downstream facing port on the EVB-USB5744 can be disabled if desired. When
both DP & DM signals are pulled up to +3.3V, by default the USB5744 automatically
disables the port, reports the corrected number of available ports to the host, and drives
the PRT_CTRL line for the disabled port(s) low.
To enable a port, use its Port Enable switch to select the “EN.” position. The associated
“Enabled” LED will light.
To disable a port, slide its Port Enable switch to the “Dis.” position. The “Enabled” LED
will extinguish.