English
Language : 

MIC50395 Datasheet, PDF (6/6 Pages) Micrel Semiconductor – Six Decade Counter / Display Decoder Not Recommended for New Designs
MIC50395/50396/50397
Dynamic Operating Conditions
Symbol
Parameter
Min
Max
Units
fCI
Count Input Frequency
0
1.00
MHz
fSI
Scan Input Frequency
0
20
kHz
tCPW
Count Pulse Width
400
ns
tSPW
Store Pulse Width
2.0
µs
tSS
Store Setup Time
0
µs
tCIS
Count Inhibit Setup Time
0
µs
tUDS
Up/Down Setup Time
–0.75
µs
tCPW
Clear Pulse Width
2.0
µs
tCS
Clear Setup Time
–0.5
µs
tOA
Zero Access Time
3.0
µs
tOH
Zero Hold Time
1.5
µs
tCA
Carry Access Time
1.5
µs
tCH
Carry Hold Time
0.9
µs
tEA
Equal Access Time
2.0
µs
tEH
Equal Hold Time
1.5
µs
tL
Load Time
1/6 fSI
Note 8: Measured at 50% duty cycle.
Note 9: If carry, equal, or zero outputs are used, the count frequency will be limited by their respective output times.
Note 10: The count pulse width must be greater than the carry access time when using the carry output.
Note 11: The positive edge of the count input is the t = 0 reference.
Note 12: Measured from negative edge of count input.
Micrel
Notes
8,9
10
11
11
11
11
11
11
11
11
12
11
11
8
August 1998
8-9