English
Language : 

MIC2010 Datasheet, PDF (5/9 Pages) Micrel Semiconductor – USB Power Controller Advance Information
MIC2010
Micrel
Symbol
VOH
TH
TS
tDLY
tOC
tON(MAIN)
tOFF(MAIN)
tr(MAIN)
tf(MAIN)
tON(AUX)
tOFF(AUX)
tr(AUX)
tf(AUX)
tXMA
tXAM
Parameter
Condition
FAULT1, 2 Output High Voltage
IFAULT = –20µA
(MIC2010-1P, 2P), (MIC2070-1P, 2P)
MAIN to S3# Hold Time, Note 7
Figure 5
MAIN to S3# Set-up Time, Note 7 Figure 5
FAULT Delay Filter Response Time Output shorted to ground, Figure 4
(Overcurrent only), Note 8
Overcurrent Response Time
Output shorted to ground, Figure 4
MAIN output
AUX output
MAIN Output Turn-On Time
MAIN Output Turn-Off Time
MAIN Output Rise Time
MAIN Output Fall Time
AUX Output Turn-On Time
AUX Output Turn-Off Time
AUX Output Rise Time
AUX Output Fall Time
MAIN to AUX
Cross Conduction Time, Note 9
RL = 10Ω, CL = 1µF, Figure 3
RL = 10Ω, CL = 1µF, Figure 3
RL = 10Ω, CL = 1µF, Figure 3
RL = 10Ω, CL = 1µF, Figure 3
RL = 50Ω, CL = 1µF, Figure 3
RL = 50Ω, CL = 1µF, Figure 3
RL = 50Ω, CL = 1µF, Figure 3
RL = 50Ω, CL = 1µF, Figure 3
S3# transition to 0
AUX to MAIN
Cross Conduction Time, Note 9
S3# transition to 1
Min Typ Max Units
4
V
5
ms
0
ms
5
10
20
ms
2
µs
2
µs
2
ms
35
µs
2
ms
32
µs
0.6
ms
120
µs
0.5
ms
115
µs
5
7.5
ms
5
7.5
ms
Note 1.
Note 2.
Note 3.
Note 4.
Note 5.
Note 6.
Note 7.
Note 8.
Note 9.
Exceeding the absolute maximum rating may damage the device.
The device is not guaranteed to function outside its operating rating.
Devices are ESD sensitive. Handling precautions recommended. Human body model, 1.5k in series with 100pF.
All voltages are referenced to ground.
For MIC2070-1(P) OFF occurs when VEN < 0.8V and ON occurs when VEN > 2.4V. For MIC2070-2(P) OFF occurs when VEN > 2.4V and ON
occurs when VEN < 0.8V.
Current-limit threshold is defined by the current-limit factor divided by RSET.
Guaranteed by design. Not production tested.
Assumes only one channel in current-limit. Delay circuitry is shared among channels so it is possible for tDLY to be 40ms max if one channel
enters current-limit as the other is about to time-out.
Cross conduction time is the duration in which both MAIN and AUX internal switches are on subsequent to S3# transitioning.
Test Circuit
Device
IOUT
Under OUT
Test
RL CL
VOUT
Timing Diagram
VOUT
tr
90%
10%
tf
90%
10%
September 2000
5
MIC2010/2070