English
Language : 

SM840002 Datasheet, PDF (4/9 Pages) Micrel Semiconductor – ClockWorks™ Dual 10-Gigabit/Gigabit Ethernet 62.5MHz, 125MHz, or 156.25MHz
Micrel, Inc.
SM840002
Absolute Maximum Ratings(1)
Supply Voltage (VDD)...................................................+4.6V
Input Voltage (VIN) ................................ –0.50V to VDD+0.5V
Output Voltage (VOUT) .......................... –0.50V to VDD+0.5V
Lead Temperature (soldering, 20sec.)....................... 260°C
Storage Temperature (Ts) .........................–65°C to +150°C
Operating Ratings(2)
Supply Voltage (VDDO) .......................... +2.375V to +3.465V
Supply Voltage (VDD, VDDA) ................... +2.375V to +3.465V
Ambient Temperature (TA) .......................... –40°C to +75°C
Junction Thermal Resistance
TSSOP (θJA)(Still Air).......................................127°C/W
DC Electrical Characteristics(3)
VDDA = VDD = 2.5V ±5%, VDDO = 2.5V ±5%, TA = –40°C to +75°C, unless noted.
Symbol
Parameter
Condition
VDD
VDDA
VDDO
IDD
IDDA
IDDO
Core Supply Voltage
Analog Supply Voltage
Output Supply Voltage
Core Supply Current
Analog Supply Current
Output Supply Current
No Load
Min.
2.375
2.375
2.375
Typ.
2.50
2.50
2.50
0.1
48
15
Max.
2.625
2.625
2.625
1
55
23
Units
V
V
V
mA
mA
mA
VDDA = VDD = 3.3V ±5%, VDDO = 3.3V ±5%, TA = –40°C to +75°C, unless noted.
Symbol Parameter
Condition
Min.
Typ.
Max.
Units
VDD
Core Supply Voltage
3.135
3.30
3.465
V
VDDA
Analog Supply Voltage
3.135
3.30
3.465
V
VDDO
Output Supply Voltage
3.135
3.30
3.465
V
IDD
Core Supply Current
0.1
1
IDDA
Analog Supply Current
49
55
mA
IDDO
Power Supply Current
No Load
25
32
mA
Notes:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied
at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3. The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established.
November 2010
4
M9999-110810
hbwhelp@micrel.com or (408) 955-1690