English
Language : 

MIC284_05 Datasheet, PDF (4/20 Pages) Micrel Semiconductor – Two-Zone Thermal Supervisor
MIC284
Micrel, Inc
Symbol
Parameter
Serial Data I/O Pin (DATA)
VOL
Low Output Voltage
Note 6
VIL
Low Input Voltage
VIH
High Input Voltage
CIN
Input Capacitance
ILEAK
Input current
Serial Clock Input (CLK)
VIL
Low Input Voltage
VIH
High Input Voltage
CIN
Input Capacitance
ILEAK
Input current
Status Output (/INT)
VOL
Low Output Voltage,
Note 6
tINT
Interrupt Propagation Delay,
Note 7, 8
tnINT
Interrupt Reset Propagation Delay,
Note 7
T_SET0
Default T_SET0 Value
T_HYST0 Default T_HYST0 Value
T_SET1
Default T_SET1 Value
T_HYST1 Default T_HYST1 Value
Over-Temperature Output (/CRIT)
VOL
Low Output Voltage,
Note 6
tCRIT
/CRIT Propagation Delay,
Note 7, 8
tnCRIT
/CRIT Reset Propagation Delay,
Note 7
CRIT1
Default CRIT1 Value
nCRIT1
Default nCRIT1 Value
Serial Interface Timing (Note 7)
t1
CLK (Clock) Period
t2
Data In Setup Time to CLK High
t3
Data Out Stable After CLK Low
t4
DATA Low Setup Time to CLK Low
t5
DATA High Hold Time
After CLK High
Condition
Min Typ Max Units
IOL = 3mA
IOL = 6mA
2.7V ≤ VDD ≤ 5.5V
2.7V ≤ VDD ≤ 5.5V
0.4
V
0.8
V
0.3VDD V
0.7VDD
V
10
pF
±0.01 ±1
µA
2.7V ≤ VDD ≤ 5.5V
2.7V ≤ VDD ≤ 5.5V
0.3VDD V
0.7VDD
V
10
pF
±0.01 ±1
µA
IOL = 3mA
IOL = 6mA
from TEMP > T_SET or TEMPx < T_HYSTx
to INT < VOL, FQ = 00, RPULLUP = 10kΩ
from any register read to /INT > VOH
FQ = 00, RPULLUP = 10kΩ
tPOR after VDD > VPOR
81
tPOR after VDD > VPOR
76
tPOR after VDD > VPOR
97
tPOR after VDD > VPOR
92
IOL = 3mA
IOL = 6mA
from TEMPx > T_SETx or TEMPx < T_HYSTx
to INT < VOL, FQ = 00, RPULLUP = 10kΩ
from TEMPx < nCRITx to /CRIT > VOH
FQ = 00, RPULLUP = 10kΩ
tPOR after VDD > VPOR
97
tPOR after VDD > VPOR
92
2.5
100
0
start condition
100
stop condition
100
0.4
V
0.8
V
tCONV+1 µs
1
µs
81
81
°C
76
76
°C
97
97
°C
92
92
°C
0.4
V
0.8
V
tCONV+1 µs
1
µs
97
97
°C
92
92
°C
µs
ns
ns
ns
ns
Note 1.
Note 2.
Note 3.
Note 4.
Note 5.
Note 6.
Note 7.
Note 8.
Note 9.
Exceeding the absolute maximum rating may damage the device.
The device is not guaranteed to function outside its operating rating.
Devices are ESD sensitive. Handling precautions recommended.
Human body model: 1.5k in series with 100pF. Machine model: 200pF, no series resistance.
Final test on outgoing product is performed at TA = TBD°C.
TD is the temperature of the remote diode junction. Testing is performed using a single unit of one of the transistors listed in Table 6.
Current into this pin will result in self-heating of the MIC284. Sink current should be minimized for best accuracy.
Guaranteed by design over the operating temperature range. Not 100% production tested.
tCONV = tCONV0 + tCONV1. tCONV0 is the conversion time for the local zone; tCONV1 is the conversion time for the remote zone.`
Accuracy specification does not include quantization noise, which may be as great as ±1⁄2LSB (±0.5°C).
MIC284
4
September 2005