English
Language : 

KSZ8001SL Datasheet, PDF (32/46 Pages) Micrel Semiconductor – 1.8V, 3.3V 10/100BASE-T/TX/FX Physical Layer Transceiver
Micrel
Address
1f:14
1f:13
1f.12
1f.11
1f.10
1f.9
1f.8
1f.7
1f.6
1f.5
1f.4:2
1f.1
1f.0
Name
MDI/MDI-X
Select
Pairswap
disable
Energy detect
Force link
Power Saving
Interrupt Level
Enable Jabber
Auto-
Negotiation
Complete
Enable Pause
(Flow-Control
Result)
PHY Isolate
Operation
Mode
Indication
Enable SQE
test
Disable Data
Scrambling
Description
When Auto MDI/MDI-X is disabled,
Mode
RW
0 = Transmit on TX+/- (pins 41,40)
Receive on RX+/- (pins 33,32)
1 = Transmit on RX+/- (pins 33,32)
Receive on TX+/- (pins 41,40)
1 = disable MDI/MDIX
RW
0 = enable MDI/MDIX
1 = presence of signal on RX+/- analog wire RO
pair
0 = no signal detected on RX+/-
1 = force link pass
RW
0 = normal link operation
This bit bypasses the control logic and allow
transmitter to send pattern even if there is no
link.
1 = enable power saving
RW
0 = disable
1 = interrupt pin active high
RW
0 = active low
1 = enable jabber counter
RW
0 = disable
1 = auto-negotiation complete
RO
0 = not complete
This bit has the same definition as register 1.5.
1 = flow control capable
RO
0 = no flow control
1 = PHY in isolate mode
RO
0 = not isolated
[000] = still in auto-negotiation
RO
[001] = 10BASE-T half duplex
[010] = 100BASE-TX half duplex
[011] = default
[101] = 10BASE-T full duplex
[110] = 100BASE-TX full duplex
[111] = PHY/MII isolate
1 = enable SQE test
RW
0 = disable
1 = disable scrambler
RW
0 = enable
Default
0
0
0
0
1
0
1
0
0
0
0
0
0
KSZ8001
June 2009
Revision 1.04
32