MIC59P50_11 Datasheet, PDF (3/5 Pages) Micrel Semiconductor – 8-Bit Parallel-Input Protected Latched Driver
MIC59P50
Micrel
Electrical Characteristics
VDD = 5V; TA = +25°C; unless noted.
Limits
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
Output Leakage Current
Collector-Emitter
Saturation Voltage
Input Voltage
Input Resistance
Flag Output Current
Flag Output Leakage
Supply Current
Clamp Diode
Leakage Current
Over-Current Threshold
Start-Up Voltage
Minimum Operating VDD
Clamp Diode Forward Voltage
Thermal Shutdown
ICEX
VCE(SAT)
VIN(0)
VIN(1)
RIN
IOL
IOH
IDD(ON)
(One output
active)
IDD(ON)
(All outputs
active)
IDD(OFF)
(Total)
IR
ILIM
VSU
VDD MIN
VF
VCE = 80V, TA = +25°C
VCE = 80V, TA = +70°C
IC = 100 mA
IC = 200 mA
IC = 350 mA
VDD = 12V
VDD = 10V
VDD = 5.0V Note 3
VDD = 12V
VDD = 10V
VDD = 5.0V
VOL = 0.4V
VOH = 12.0V
VDD = 12V, Outputs Open
VDD = 10V, Outputs Open
VDD = 5.0V, Outputs Open
VDD = 12V, Outputs Open
VDD = 10V, Outputs Open
VDD = 5.0V, Outputs Open
VDD = 12V, Outputs Open, Inputs = 0V
VDD = 5.0V, Outputs Open, Inputs = 0V
VR = 80V, TA = +25°C
VR = 80V, TA = +70°C
Each Output
Note 4
IF = 350 mA
50
µA
100
0.9
1.1
V
1.1
1.3
1.3
1.6
1.0
V
10.5
8.5
3.5
50
200
kΩ
50
300
50
600
15
mA
50
nA
3.3
4.5
mA
3.1
4.5
2.4
3.6
6.4 10.0 mA
6.0
9.0
4.7
7.5
3.0
4.5
mA
2.2
3.6
50
µA
100
500
mA
3.5
4.0
4.5
V
3.0
3.5
4.0
V
1.7
2.0
V
165
°C
Thermal Shutdown Hysteresis
10
NOTE 3: Operation of these devices with standard TTL or DTL may require the use of appropriate pull-up resistors to insure a minimum logic “1”.
NOTE 4: Undervoltage lockout is guaranteed to release device at no more than 4.5V and disable the device at no less than 3.0V input logic voltage.
Truth Table
INN
Strobe
0
1
Clear
0
1
1
0
X
X
1
X
X
X
X
0
0
X
0
0
X = Irrelevant
t–1 = previous output state
t = present output state
Output
Enable
0
0
X
1
0
0
OUTN
t–1
t
X
OFF
X
ON
X
OFF
X
OFF
ON
ON
OFF OFF
Information present at an input is transferred to its latch when
the STROBE is high. A high CLEAR input will set all latches
to the output OFF condition regardless of the data or STROBE
input levels. A high OUTPUT ENABLE will set all outputs to
the off condition, regardless of any other input conditions.
When the OUTPUT ENABLE is low, the outputs depend on
the state of their respective latches. If current shutdown is
activated, the OUTPUT ENABLE must be pulsed high to
restore operation and reset the Flag. Over temperature
faults are not latched and require no reset pulse.
7-60