Absolute Maximum Ratings(1)
Supply Voltage (VIN) ........................................ –0.3V to +6V
Output Switch Voltage (VSW) .............................. –1V to +6V
Output Switch Current (ISW)............................................10A
Logic Input Voltage (VEN) .................................. –0.3V to VIN
Storage Temperature (Ts) ........................... –60°C to 150°C
ESD Rating(3).......................................................2kV (HBM)
Operating Ratings(2)
Supply Voltage (VIN)..................................... +2.7V to +5.5V
Logic Input Voltage (VEN, VLOWQ)............................ 0V to VIN
Junction Temperature (TJ) ........................ –40°C to +125°C
Junction Thermal Resistance
3x3 MLF-12 (θJA) ...............................................60°C/W
Electrical Characteristics(4)
VIN = VEN = 3.6V; L = 1µH; COUT = 4.7µF; TA = 25°C, unless noted. Bold values indicate –40°C< TJ < +125°C.
Parameter
Condition
Min Typ Max
Supply Voltage Range
2.7
5.5
Under-Voltage Lockout
Threshold
(turn-on)
2.45 2.55 2.65
UVLO Hysteresis
100
Quiescent Current
VFB = 0.9 * VNOM (not switching)
720
950
Shutdown Current
[Adjustable] Feedback
Voltage
VEN = 0V
± 1%
± 2% (over temperature)
0.1
5
0.99
1
1.01
0.98
1.02
FB pin input current
1
100
Current Limit in PWM Mode
Output Voltage Line
Regulation
VFB = 0.9 * VNOM
VOUT > 2.2V; VIN = VOUT + 500mV to 5.5V; ILOAD = 20mA
VOUT < 2.2V; VIN = 2.7V to 5.5V; ILOAD = 20mA
8
10
0.13
Output Voltage Load
Regulation
20mA < ILOAD < 3A
0.2
1
PWM Switch ON-
Resistance
ISW = 50mA VFB = 0.7VFB_NOM (High Side Switch)
95
20
300
Oscillator Frequency
0.9
1
1.1
Enable Threshold
0.5 0.85
1.3
Enable Input Current
0.1
2
Soft Start Time
VOUT =10% to VOUT = 90%
450
Over-Temperature
160
Shutdown
over-Temperature
20
Hysteresis
Power Good Range
±7
±10
Power Good Resistance
IPGOOD
145
250
Notes:
1. Exceeding the absolute maximum rating may damage the device.
2. The device is not guaranteed to function outside its operating rating.
3. Devices are ESD sensitive. Handling precautions recommended. Human body model, 1.5kΩ in series with 100pF.
4. Specification for packaged product only.
Units
V
V
mV
µA
µA
V
V
nA
A
%
%
mΩ
mΩ
MHz
V
µA
µs
°C
°C
%
Ω