English
Language : 

MIC261201 Datasheet, PDF (22/30 Pages) Micrel Semiconductor – 28V, 12A Hyper Speed Control™ Synchronous DC/DC Buck Regulator
Micrel, Inc.
Thermal Measurements
Measuring the IC’s case temperature is recommended to
insure it is within its operating limits. Although this might
seem like a very elementary task, it is easy to get
erroneous results. The most common mistake is to use
the standard thermal couple that comes with a thermal
meter. This thermal couple wire gauge is large, typically
22 gauge, and behaves like a heatsink, resulting in a
lower case measurement.
Two methods of temperature measurement are using a
smaller thermal couple wire or an infrared thermometer.
If a thermal couple wire is used, it must be constructed
of 36 gauge wire or higher then (smaller wire size) to
minimize the wire heat-sinking effect. In addition, the
thermal couple tip must be covered in either thermal
grease or thermal glue to make sure that the thermal
couple junction is making good contact with the case of
the IC. Omega brand thermal couple (5SC-TT-K-36-36)
is adequate for most applications.
Wherever possible, an infrared thermometer is
recommended. The measurement spot size of most
infrared thermometers is too large for an accurate
reading on a small form factor ICs. However, a IR
thermometer from Optris has a 1mm spot size, which
makes it a good choice for measuring the hottest point
on the case. An optional stand makes it easy to hold the
beam on the IC for long periods of time.
MIC261201
July 2011
22
M9999-071311-A