English
Language : 

MIC284 Datasheet, PDF (16/20 Pages) Micrel Semiconductor – Two-Zone Thermal Supervisor Advance Information
MIC284
Remote Temperature Result Register
REMOTE TEMPERATURE RESULT (TEMP1)
8-Bit Read Only
D[7]
D[6]
D[5]
D[4]
D[3]
D[2]
D[1]
D[0]
MSB
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
LSB
remote temperature data from ADC*
Micrel
Bits
D[7:0]
Function
measured temperature data for the remote
zone*
read only
Operation
TEMP1 Power-Up Value: 0000 0000b = 00h (0°C)†
TEMP1 Command Byte Value: 0001 0000b = 10h
* Each LSB represents one degree Centigrade. The values are
in a two's complement format such that 0°C is reported as
0000 0000b. See "Temperature Data Format" for more details.
† TEMP1 will contain measured temperature data for the
selected zone after the completion of one conversion.
Remote Temperature Hysteresis Register
REMOTE TEMPERATURE HYSTERESIS (T_HYST1)
8-Bit Read/Write
D[7]
D[6]
D[5]
D[4]
D[3]
D[2]
D[1]
D[0]
MSB
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
LSB
remote temperature hysteresis setting
Bits
Function
D[7:0] remote temperature hysteresis setting*
read/write
Operation
T_HYST1 Power-Up Value: 0101 1100b = 5Ch (+92°C)
T_HYST1 Command Byte Value: 0001 0010b = 12h
* Each LSB represents one degree Centigrade. The values are
in a two's complement format such that 0°C is reported as
0000 0000b. See "Temperature Data Format" for more details.
Remote Temperature Setpoint Register
REMOTE TEMPERATURE SETPOINT (T_SET1)
8-Bit Read/Write
D[7]
D[6]
D[5]
D[4]
D[3]
D[2]
D[1]
D[0]
MSB
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
LSB
remote temperature setpoint
Bits
Function
D[7:0] remote temperature setpoint*
read/write
Operation
T_SET1 Power-Up Value: 0110 0001b = 61h (+97°C)
T_SET1 Command Byte Value: 0001 0011b = 13h
* Each LSB represents one degree Centigrade. The values are
in a two's complement format such that 0°C is reported as
0000 0000b. See "Temperature Data Format" for more details.
MIC284
16
September 29, 2000