Current Sensing and Limiting
The current-limit threshold is preset internally. The preset
level prevents damage to the device and external load but still
allows a minimum current of 500mA to be delivered to the
load.
The current-limit circuit senses a portion of the output MOS-
FET switch current. The current-sense resistor shown in the
block diagram is virtual and has no voltage drop. The reaction
to an overcurrent condition varies with three scenarios:
Switch Enabled into Short-Circuit
If a switch is enabled into a heavy load or short-circuit, the
switch immediately enters into a constant-current mode,
reducing the output voltage. The FLG signal is asserted
indicating an overcurrent condition.
Short-Circuit Applied to Enabled Output
When a heavy load or short-circuit is applied to an enabled
switch, a large transient current may flow until the current-
limit circuitry responds. Once this occurs the device limits
current to less than the short-circuit current limit specification.
Current-Limit Response—Ramped Load
The MIC2026/76 current-limit profile exhibits a small foldback
effect of about 200mA. Once this current-limit threshold is
exceeded the device switches into a constant current mode.
It is important to note that the device will supply current up to
the current-limit threshold.
Micrel
Fault Flag
The FLG signal is an N-channel open-drain MOSFET output.
FLG is asserted (active-low) when either an overcurrent or
thermal shutdown condition occurs. In the case of an overcur-
rent condition, FLG will be asserted only after the flag
response delay time, tD, has elapsed. This ensures that FLG
is asserted only upon valid overcurrent conditions and that
erroneous error reporting is eliminated. For example, false
overcurrent conditions can occur during hot-plug events
when a highly capacitive load is connected and causes a high
transient inrush current that exceeds the current-limit thresh-
old for up to 1ms. The FLG response delay time tD is typically
3ms.
Undervoltage Lockout
Undervoltage lockout (UVLO) prevents the output MOSFET
from turning on until VIN exceeds approximately 2.5V. Under-
voltage detection functions only when the switch is enabled.
VEN
VOUT
ILIMIT
ILOAD
IOUT
VFLG
Short-Circuit Fault
3ms typ.
delay
Thermal
Shutdown
Reached
Load and Fault Removed
(Output Reset)
Figure 1. MIC2076-2 Fault Timing: Output Reset by Removing Load
VEN
VOUT
ILIMIT
ILOAD
IOUT
VFLG
March 2000
Short-Circuit Fault
Load/Fault
Removed
3ms typ.
delay
Thermal
Shutdown
Reached
Figure 2. MIC2026-2 Fault Timing
11
MIC2026/2076