English
Language : 

FBR605 Datasheet, PDF (1/2 Pages) MIC GROUP RECTIFIERS – SINGLE PHASE BRIDGE RECTIFIER
SINGLE PHASE BRIDGE RECTIFIER
FBR605 THRU FBR610
VOLTAGE RANGE
CURRENT
50 to 1000 Volts
6.0 Ampere
FEATURES
• Low cost
• High forward surge current capacity
• Fast switching high efficiency
• High temperature soldering guaranteed:
260OC / 10 seconds, at 5 lbs. (2.3kg) tension.
MECHANICAL DATA
• Case: Molded plastic body
• Terminal: Lead solderable per MIL-STD-202E
method 208C
• Polarity: Polarity symbols marked on case
• Mounting: Thru hole for #6 screw, 5 in-lbs torque max.
• Weight: 0.13 ounce, 3.66 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
• Ratings at 25OC ambient temperature unless otherwise specified
• Single Phase, half wave, 60Hz, resistive or inductive load
• For capacitive load derate current by 20%
0.445( 11.3)
0.405( 10.3)
BR-6
0.10( 2.5) x45
0.158(
0.142(
4.0)
3.6)
DIA
+
AC
AC
-
0.620( 15.7)
0.580( 14.7)
0.445( 11.3)
0.405( 10.3)
0.620( 15.7)
0.580( 14.7)
0.270( 6.9)
0.230( 5.8)
0.85( 21.6)
MIN
0.75( 19.0) MIN
0.08( 2.0) MIN
0.042( 1.10) DIA
0.038( 0.97) TYP
Dimensions in inches and (millimeters)
SYMBOLS FBR605 FBR61 FBR62 FBR64 FBR66
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
VRRM
50
100 200
400
600
VRMS
35
70 140
280
420
VDC
50 100 200
400
600
Maximum Average Forward
Rectified Output Current, at
TC = 50℃ (Note 1)
TA = 25℃ (Note 2)
I(AV)
6.0
3.0
Peak Forward Surge Current
8.3mS single half sine wave superimposed on
IFSM
125
rated load (JEDEC method)
Rating for Fusing (t<8.3mS)
I2t
64
Maximum Instantaneous Forward Voltage drop per
Bridge element at 3.0 A
VF
1.2
Maximum DC Reverse Current at Rated
DC Blocking Voltage per element
TA = 25℃
TA = 100℃
IR
10
1.0
Maximum Reverse Recovery Time (Note3) TJ=25℃
TRR
150
250
Isolation Voltage from case to lug
VISO
2500
Typical Thermal Resistance (Note 1 )
RθJc
8.0
Operating Temperature Rang
TJ
-55 to +150
Storage Temperature Rang
TSTG
-55 to +150
Notes:
1. Unit mounted on 6.0” x 5.5” x 0.11” thick (15×14×0.3cm) AL plate
2. Unit mounted on P.C. Board 0.375” (9.5mm) lead length with 0.47”×0.47” (12×12mm) copper pads.
3. Reverse Recovery test conditions: IF=0.5A, IR=0.5A, IRR=0.25A
FBR68 FBR610
800 1000
560 700
800 1000
UNIT
Volts
Volts
Volts
Amps
1.3
500
Amps
A2s
Volts
µA
mA
nS
Volts
OC/W
OC
OC
E-mail: sales@cnmic.com Web Site: www.cnmic.com