EDFS1A Datasheet, PDF (1/2 Pages) MIC GROUP RECTIFIERS – SURFACE MOUNT FAST RECOVERY BRIDGE
SURFACE MOUNT FAST RECOVERY BRIDGE
EDFS1A THRU EDFS1D
VOLTAGE RANGE
CURRENT
50 to 200 Volts
1.0 Ampere
FEATURES
• Glass passivated chip junction
• Superfast recovery times for high efficiency
• Ideal for surface mounted applications
• Low leakage
• High forward surge current capability
• High temperature soldering guaranteed:
260℃/10 seconds at terminals
MECHANICAL DATA
• Case: Molded plastic body
• Epoxy: UL94V-0 rate flame retardant
• Polarity: Molded on body
• Leadp: Plated terminals solderable per MIL-STD-202E
method 208C
• Weight: 0.04 ounce, 1.0 gram
DFS
0.205 (5.2)
0.195 (5.0)
-
+
0.404 (10.3)
0.386 (9.80)
0.255 (6.5)
0.245 (6.2)
-
-
0.047 (1.20)
0.040 (1.02)
0.335 (8.51)
0.320 (8.13)
45 O
0.060 (1.524)
0.040 (1.016)
0.013 (0.330)
0.003 (0.076)
0.013 (0.330)
0.009 (0.241)
.135 (3.4)
.115 (2.9)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
• Ratings at 25℃ ambient temperature unless otherwise specified
• Single Phase, half wave, 60Hz, resistive or inductive load
• For capacitive load derate current by 20%
SYMBOLS EDFS1A
Maximum Reverse Peak Repetitive Voltage
VRRM
50
Maximum RMS Voltage
VRMS
35
Maximum DC Blocking Voltage
VDC
50
Maximum Average Forward Rectified Output
Current, 0.06”(1.5mm) lead length at TA=40℃
(Note 2)
I(AV)
Peak Forward Surge Current
8.3ms single half sine wave superimposed on
rated load (JEDEC Method)
Rating for Fusing (t<8.3ms)
IFSM
I2t
Maximum Instantaneous Forward Voltage drop
Per Bridge element 1.0A
VF
Maximum Reverse Current at rated
DC blocking voltage per element
TA=25℃
TA=125℃
IR
Maximum Reverse Recovery Time (Note 1)
Trr
Typical Junction Capacitance (Note 3)
CJ
Typical Thermal Resistance (Note 2)
RΘJA
Operating and Storage Temperature Range
TJ ,TSTG
Notes: 1. Test condition: If=0.5A, Ir=1.0A,IRR=0.25A
2.Unit mounted on P.C.B. with 0.51”×0.51” ( 13×13mm) copper pads.
3. Measured at 1.0MHz and applied reverse voltage of 4.0 Volts.
EDFS1B
100
70
100
EDFS1C
150
106
150
1.0
50
10
1.05
5.0
0.5
50
25
40
(-55 to +150)
EDFS1D
200
140
200
UNIT
Volts
Volts
Volts
Amps
Amps
A2s
Volts
µAmps
mAmps
nS
pF
℃/W
℃
E-mail: sales@cnmic.com Web Site: www.cnmic.com